ES-0892 Rev.11
10BXA
High-density Signal Conditioners 10-RACK
STANDARD RACK
(with air manifold)
Functions & Features
• Standard 19" rack for I/P transducers (model: 10VP)
• Line power access at the terminal card, supplied via the rear rack bus
• Supply pressure at the manifold plug
• Other 10-Rack signal conditioners are also mountable
MODEL: 10BXA–R[1]
ORDERING INFORMATION
• Code number: 10BXA-R[1]
Specify a code from below for [1].
(e.g. 10BXA-R/Q)
• Specify the specification for option code /Q
(e.g. /C01)
POWER INPUT
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[1] OPTIONS
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to our web site.)
Power supply and signal conditioner side of the main PWB are not coated.
/C01
: Silicone coating
/C02
: Polyurethane coating
/C03
: Rubber coating
GENERAL SPECIFICATIONS
Construction
: Metal plates assembly
Coating
: Zn-Cr (black), alumetized steel
Capacity
: 16 positions
Connection
•
Power input
: M4 screw terminals
(torque 0.8 N·m)
Screw terminal
: Nickel-plated steel
•
Pneumatic
: Rc 3/8" female (torque ≤ 12 N·m)
Screw terminal
: Nickel-plated brass
Manifold
: Aluminium alloy
Isolation
: Power to FG
INSTALLATION
Operating temperature
: -5 to +55°C (23 to 131°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Mounting
: JIS/EIA standard rack or angle bracket
Weight
: 4.5 kg (9.9 lb)
PERFORMANCE
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 500 V AC @ 1 minute (power to FG)
Maximum supply pressure
: 196 kPa
(2 kgf/cm
2
, 1.96 bar, 28 psig)
MOUNTING REQUIREMENTS
CONNECTION DIAGRAM
DIMENSIONS unit: mm (inch)