ES-4433 Rev.1

20VS1F

Hybrid IC Isolation Amplifiers 20 Series

ISOLATION AMPLIFIER

(4 channels, input isolation)
Functions & Features
• Being used for printed wiring board installation
• Up to 2000 V isolation between input to output or power input
•Isolation on 4 input channels
• Small installation area in printed wiring board
• Gain adjustable range, × 1 to × 100
• Power 15 V DC
Typical Applications
• Galvanically isolating the I/O circuits of microprocessor from the field side to reduce external noise
• Enabling electronic manufacturers to save efforts and cost for the development of isolation circuits for small-lot products
 

MODEL: 20VS1F–4W4W–U

ORDERING INFORMATION

• Code number: 20VS1F-4W4W-U

I/O

4W4W:
INPUT RANGE ±10 V DC
OUTPUT RANGE ±10 V DC

POWER INPUT

DC Power
U: 15 V DC

GENERAL SPECIFICATIONS

Construction: Hybrid IC
PWB coating: Silicone
Isolation: Input to output or power input, between inputs

INPUT SPECIFICATIONS

DC Voltage
Input
: -10 – +10 V DC
Input resistance: ≥ 1 MΩ  (10 kΩ in power failure)
Overload input voltage: ±30 V DC continuous
Input offset voltage: ±20 mV
Input bias current: 0.5 nA TYP. (@25°C)

OUTPUT SPECIFICATIONS

DC Voltage: -10 – +10 V DC
Load resistance: ≥ 10 kΩ
Output impedance: ≤ 1 Ω

INSTALLATION

Power input
DC: Operational voltage range: Rating ±10 %,
ripple 2 %p-p max.; approx. 20 mA with no load
Operating temperature: -20 to +70°C (-4 to +158°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Soldering to the printed wiring board
Weight: 30 g (1.1 oz)

PERFORMANCE in percentage of span

Unless otherwise specified, G = 1.
Linearity: ±0.05 %
Temp. coefficient: 50 ppm/°C (28 ppm/°F)
Frequency characteristics: Approx. 10 kHz, -3 dB
Response time: ≤ 60 µsec. (0 – 90 %)
Conversion gain: ×1 ±5 %
Gain adjustable range: × 1 to × 100
Line voltage effect: ±0.05 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute
(input to output or power)
1000 V AC @ 1 minute (between inputs)
CMRR: ≥ 100 dB (500 V AC  50/60 Hz)

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

APPLICATION EXAMPLE

The resistance of R1 must be between 1 kΩ and 200 kΩ.