ES-4404 Rev.5

20VS3

Hybrid IC Isolation Amplifiers 20 Series

ISOLATION AMPLIFIER

(3-port isolation)
Functions & Features
• Being used for printed wiring board installation
• Isolating between input, output and power
• Isolation between input, output and power supply up to 1500 V AC
• High-linearity
• Low power consumption
• Saving installation space
• Power 15 V DC
Typical Applications
• Isolating the field and input or output circuit of microprocessor to reduce noise from field
• Available for manufacturers of small-lot products to omit the development of isolation circuit

MODEL: 20VS3

ORDERING INFORMATION

Code number: 20VS3–U
  Input range ±5 V DC
  Output range ±5 V DC

Code number: 20VS3–5W4W–U
  Input range ±5 V DC
  Output range ±10 V DC

Code number: 20VS3–4W4W–U
  Input range ±10 V DC
  Output range ±10 V DC

POWER INPUT

DC Power
U: 15 V DC

GENERAL SPECIFICATIONS

Construction: Hybrid IC
Housing material: Epoxy resin
Isolation: Input or reference voltage source to output to power supply

INPUT SPECIFICATIONS

DC Voltage
Input : -5 – +5 V DC
  Input resistance: ≥ 1 MΩ  (10 kΩ in power failure)
Input : -10 – +10 V DC
  Input resistance: ≥ 350 kΩ  (10 kΩ in power failure)
Overload input voltage: 30 V DC continuous
Input offset voltage: ±15 mV
Input bias current: 2 nA TYP. (@25°C)

OUTPUT SPECIFICATIONS

DC Voltage:
• -5 – +5 V DC
  Load resistance: ≥ 2 kΩ
• -10 – +10 V DC
  Load resistance: ≥ 4 kΩ
Output impedance: ≤ 1 Ω

REFERENCE VOLTAGE SOURCE

Output voltage: ±7.1 V DC ±10 %
Load current: ≤ 2 mA

INSTALLATION

Power input
DC: Operational voltage range:  
 Rating ±5 %; approx. 7 mA with no load;
 ripple 2 % p-p max.
Operating temperature: -10 to +70°C (14 to 158°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Soldering to the printed wiring board
Weight: 10 g (0.35 oz)

PERFORMANCE in percentage of span

Unless otherwise specified, G = 1.
(G = 2 for 20VS3-5W4W; G = -2 for inverting amplifier circuit of 20VS3-4W4W)
Linearity: ±0.001 % TYP. (±0.05 % max.)
Temp. coefficient:
Offset drift 5 ppm/°C TYP. (20 ppm/°C max.)
Span drift 10 ppm/°C TYP. (50 ppm/°C max.)
Frequency characteristics: Approx. 1 kHz, -3 dB
Response time: ≤ 450 μsec. (0 – 90 %)
Conversion gain: ×1 ±1 % (×2 ±1 % for 20VS3-5W4W)
Line voltage effect: ±0.05 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @1 minute (input or reference voltage source to output to power)
CMRR: ≥ 100 dB (500 V AC  50/60 Hz)

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

APPLICATION EXAMPLE

The total resistance of the resistors connected to the amplifier must be max. 100 kΩ.