ES-4414 Rev.4

20VS5-200

Hybrid IC Isolation Amplifiers 20 Series

ISOLATION AMPLIFIER

(ultra-high speed response, input isolation)
Functions & Features
• Being used for printed wiring board installation
• Response time 10 μs
• Isolation between input to output or power supply
up to 1500 V AC
• Power 15V DC
Typical Applications
• Isolating the field and iput circuit of microprocessor to reduce noise from field
• Available for manufacturers of small-lot products to omit the development of isolation circuit
 

MODEL: 20VS5–200–U

ORDERING INFORMATION

 • Code number: 20VS5-200-U
INPUT RANGE -5 – +5 V DC
OUTPUT RANGE -5 – +5 V DC

POWER INPUT

DC Power
U: 15 V DC

GENERAL SPECIFICATIONS

Construction: Hybrid IC
Housing material: Epoxy resin
Isolation: Input or reference voltage source to output or power supply

INPUT SPECIFICATIONS

DC Voltage
Input
: -5 – +5 V DC
Input resistance: ≥ 1 MΩ  (10 kΩ in power failure)
Overload input voltage: 30 V DC continuous
Input offset voltage: ±129 mV (15 mV TYP.)
Input bias current: 100 pA TYP. (@25°C)

OUTPUT SPECIFICATIONS

DC Voltage: -5 – +5 V DC
Load resistance: ≥ 2 kΩ
Output impedance: ≤ 1 Ω

REFERENCE VOLTAGE SOURCE

Output voltage:
±14 V DC TYP. (+15 V power supply)
±10 V DC TYP. (+11.5 V power supply)
Load current: ≤ 2 mA

INSTALLATION

Power input
DC:
Operational voltage range 11.5 – 16 V;
ripple 2 %p-p max.; approx. 40 mA with no load
Operating temperature: -10 to +70°C (14 to 158°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Soldering to the printed wiring board
Weight: 8 g (0.28 oz)

PERFORMANCE in percentage of span

Linearity: ±0.5 % @ G = 1
Temp. coefficient:
Offset drift 50 ppm/°C
Span drift 200 ppm/°C
Frequency characteristics: Approx. 50 kHz, -3 dB
Response time: ≤ 10 µsec. (0 – 90 %)
Conversion gain: ×1 ±8 % max.
Gain adjustable range: × 1 to × 10
Ripple: ±7 %p-p max. (G = 1)
Line voltage effect: ±0.5 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @1 minute (input or reference voltage source to output or power)
CMRR: ≥ 100 dB (500 V AC  50/60 Hz)

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

APPLICATION EXAMPLE

The total resistance of the resistors connected to the amplifier must be max. 20 kΩ.