ES-9531 Rev.11
40LV
Digital Panel Meters 40 Series
DC INPUT DIGITAL PANEL METER
(3½ digit, without scaling)
Functions & Features
• High visible 0.8” (20.3 mm) LED
• Easy to use
MODEL: 40LV–[1]–R[2]
ORDERING INFORMATION
• Code number: 40LV–[1]–R[2]
Specify a code from below for each of [1] and [2].
(e.g. 40LV-V1-R/Q)
• Specify the specification for option code /Q
(e.g. /C01)
[1] INPUT
Current
A1
: ±199.9 μA DC (Input resistance 1 kΩ)
A2
: ±1.999 mA DC (Input resistance 100 Ω)
A3
: ±19.99 mA DC (Input resistance 10 Ω)
A4
: ±199.9 mA DC (Input resistance 1 Ω)
A5
: ±1.999 A DC (Input resistance 0.1 Ω)
Voltage
V1
: ±199.9 mV DC (Input resistance 100 MΩ)
V2
: ±1.999 V DC (Input resistance 100 MΩ)
V3
: ±19.99 V DC (Input resistance 10 MΩ)
V4
: ±199.9 V DC (Input resistance 10 MΩ)
(CE not available)
POWER INPUT
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±20 %, ripple 10 %p-p max.)
[2] OPTIONS
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to our web site.)
Moving parts and indicators are not coated.
/C01
: Silicone coating
/C02
: Polyurethane coating
/C03
: Rubber coating
GENERAL SPECIFICATIONS
Construction
: Panel flush mounting
Connection
: M3 screw terminals (torque 0.6 N·m)
Solderless terminal
: Refer to the drawing at the end of the section.
Recommended manufacturer
: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,ltd
Applicable wire size
: 0.25 to 1.65 mm
2
(AWG 22 to 16)
Screw terminal
: Nickel-plated steel
Housing material
: Flame-resistant resin (gray)
Isolation
: Input to power
A/D conversion
: Dual-slope integration
Sampling rate
: 2.5 times/sec. (400 msec.)
■Recommended solderless terminal
DISPLAY
Display
: 3 ½ digits of 20.3 mm height, red LED
Display range
: -1999 to 1999
Decimal point position
: 10
-1
, 10
-2
, 10
-3
or none
(3 positions selectable by short circuit between terminals 5, 6 or 7 to 3)
Polarity
: Minus (–) sign added automatically according to the input signal.
Over-range indication
: 1 for positive; -1 for negative
Engineering unit indication
: Sticker label attached
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,
cm, mm, m, m/sec, mm/min, cm/min, m/min,
m/h, m/s
2
, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m
3
, m
3
/sec,
m
3
/min, m
3
/h, Nm
3
/h, N·m, N/m
2
, g, kg, kg/h,
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,
kJ, MJ, rpm, sec, min, pH, %, ppm, etc.
INPUT SPECIFICATIONS
■ Hold Input
: Dry contact input
Detecting level
: ≤ 4.3 V
Sensing
: Approx. 5V, 0.7 mA DC
INSTALLATION
Power consumption
•
DC
: Approx. 0.5 W
Operating temperature
: 0 to 55°C (32 to 131°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Mounting
: Panel flush mounting
Weight
: 150 g (0.33 lb)
PERFORMANCE in percentage of reading
Accuracy
: See the table next.
Temp. coefficient
: ± (0.01 % of |rdg| + 0.1 digits) / °C
Line voltage effect
: ±1 digit over voltage range
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 1500 V AC @1 minute (input to power to ground)
STANDARDS & APPROVALS
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
DISPLAY HOLD COMMAND
To hold the display, close between HOLD and COM as shown below.
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
MOUNTING REQUIREMENTS unit: mm
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM