ES-9568 Rev.3

47NLDYT

Digital Panel Meters 47NL Series

CURRENT LOOP SUPPLY DIGITAL PANEL METER

(4½ digit, LED display type, with terminal block)
Functions & Features
• 4 ½ digit current loop supply digital panel meter
• Moving average function to suppress the display flickering
• Scaling, forced zero, low-end cutout
• Switchable between linear and square root extraction
• Max. and Min. value display
• Photo MOSFET relay alarm output
• Dedicated terminal block I/O
 

MODEL: 47NLDYT-[1]-R[2]

ORDERING INFORMATION

• Code number: 47NLDYT-[1]-R[2]
Specify a code from below for each of [1] and [2].
  (e.g. 47NLDYT-B-R/Q)
• Specify the specification for option code /Q
  (e.g. /SET)

INPUT

Current
4 – 20 mA DC (Input resistance 250 Ω)

[1] DISPLAY COLOR

R: Red
YR: Orange
G: Green
B: Blue
W: White

POWER INPUT

DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)

[2] OPTIONS

blank: none
/Q: With options (specify the specification)

SPECIFICATIONS OF OPTION: Q

EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
 (No. ESU-9568)

GENERAL SPECIFICATIONS

Construction: Panel mount type
Degree of protection: IP66; Applicable to the front of the panel meter mounted according to the specified panel cutout.
Connection: M3 screw terminals (torque 0.6 N·m)
Solderless terminal: Refer to the drawing at the end of the section.
   Recommended manufacturer: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,ltd 
  Applicable wire size: 0.25 to 1.65 mm2 (AWG 22 to 16)
Screw terminal: Nickel-plated steel
Housing material: Flame-resistant resin (gray)
Isolation: Input to alarm output to power
Setting: (Front button)
• Scaled range
• Linear, square root extraction
• Moving average
• Low-end cutout
• Others
(Refer to the operating manual for details)
Averaging: None or moving average
Lockout setting: Prohibiting certain operations; protecting settings
■Recommended solderless terminal

DISPLAY

Display: 16 mm (.63) high, 4 ½ digits, 7-segment LED
Display range: -19999 to 19999
Decimal point position: 10–1, 10–2, 10–3, 10–4 or none
Zero indication: Higher-digit zeros are suppressed.
Over-range indication: ‘-19999’ or ‘19999’ blinking for
display values out of the display range.
‘S.ERR’ and ‘Min’ or ‘Max’ blinking when the input signal is
out of the usable range.
Overload indication: 'O.L.' and 'Max' blinking when input overload.
Alarm status indication
  L indicator: Green turns on when the L alarm is tripped.
  H indicator: Red turns on when the H alarm is tripped.
  P indicator: Amber turns on when none of the other alarms
  is tripped.
  Only ‘P’ turns on when no-alarm is selected with
  alarm setpoint.
Function indicators:
Zro, Spn, D/P, Tch, Fnc, Min, Max
Display mode status and operation status, amber ON or blink
Engineering unit indication: Sticker label attached
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,
cm, mm, m, m/sec, mm/min, cm/min, m/min,
m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec,
m3/min, m3/h, Nm3/h, N·m, N/m2, g, kg, kg/h,
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,
kJ, MJ, rpm, sec, min, pH, %, ppm, etc.

SUPPLY OUTPUT

(across the terminals 1 – 2)
Output voltage:
24 - 28 V DC max. with no load
18 V DC min. at 20 mA no load
Current rating: ≤ 22 mA DC
Shortcircuit Protection
Current limited
: 35 mA max.
Protected time duration: No limit

INPUT SPECIFICATIONS

DC Current: Input resistor incorporated
Usable range: 4.00 - 20.00 mA DC
(Conformance range: -20 - +120 % of usable range)

OUTPUT SPECIFICATIONS

Alarm Output: Photo MOSFET Relay
Rating: 26.4 V DC @ 100 mA (resistive load)
ON resistance: ≤ 5 Ω

INSTALLATION

Power consumption
DC: 2.2 W max.
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 10 to 90 %RH (non-condensing)
Mounting: Screw mounting
Weight: 120 g (0.26 lb)

PERFORMANCE

Accuracy
  Display
: ±0.1 % ± 1 digit
  (Input within 1 - 100 % for square root extraction)
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Response time: ≤ 0.5 sec.
(alarm output: 0 – 100 % at 90 % setpoint)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute (input to alarm output to power to ground)

STANDARDS & APPROVALS

EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
RoHS Directive

EXTERNAL VIEW

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]

端子台の寸法図変更あり(次回変更時反映させる)、図面変更済、取説にも影響あり

MOUNTING REQUIREMENTS unit: mm [inch]

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM