Functions & Features
• Accepting a bridge type strain gauge utilized in load cells, pressure transducers
• BCD, binary, reflected binary, two's complement outputs
• Open collector or CMOS for output levels
• Output and setting can be scaled in convenient engineering unit
• Output display
Typical Applications
• Interface of analog signal to computers and PLC
• Input to a digital panel meter
 

MODEL: AD2LC–[1][2]–[3][4]

ORDERING INFORMATION

• Code number: AD2LC-[1][2]-[3][4]
Specify a code from below for each of [1] through [4].
  (e.g. AD2LC-S1C-M2/Q)
• Specify the specification for option code /Q
  (e.g. /C01/S01)

[1] INPUT STRAIN GAUGE

S1: 0.0 – 3.0 mV/V
S2: 0.0 – 10.0 mV/V
S3: 0.0 – 30.0 mV/V

[2] OUTPUT LEVEL

A: Open collector (NPN)
C: CMOS level

[3] POWER INPUT

AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
 47 – 66 Hz)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)

[4] OPTIONS

blank: none
/Q: With options (specify the specification)

SPECIFICATIONS OF OPTION: Q (multiple selections)

COATING (For the detail, refer to our web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
TERMINAL SCREW MATERIAL
/S01: Stainless steel

RELATED PRODUCTS

• Connector terminal block (model: CNT)
• Special cable (model: MCN26)

GENERAL SPECIFICATIONS

Construction: Plug-in
Connection
Input & power
: M3.5 screw terminals
Output: 26-pin connector (OMRON XG4A-2634)
Paired connector: OMRON XG4M-2630-T, XG5M-263x-N
Cover: OMRON XG5S-2612
Screw terminal: Chromated steel (standard) or stainless steel
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
Excitation adjustment: 0.1 – 12.0 V (front)
Zero adjustment: -99.99 – 99.99 % (front)
Gain adjustment: 0.000 – 9.999 (front)
Tare adjustment: -999.9 – 999.9 % (front or by contact input (Di))
Setting: (Front key pad)
• Scaled range
• Moving average
• Output code
• Available number of bits
• POL/OVF output logic
• Data output logic
• HOLD input logic
• DAV output logic
• DAV output time
• Zero and gain adjustment
• Tare adjustment
• etc.
For detailed information, refer to the instruction manual.
DISPLAY
LED
: 7 mm (.28") 7 segment, red
Number of display digits: 4 digits for DATA display; 2 digits for ITEM display
PV indication: Output signal in engineering unit
Overrange indication: LEDs blinking
Power saving mode: Displays turn off if the keys are untouched for a preset time period
PL1 (POL) LED: Red LED turns on at negative polarity.
PL2 (HOLD) LED: Red LED turns on at HOLD.

INPUT SPECIFICATIONS

Strain Gauge Input
Strain Gauge
Sensor sensitivity
setting
S1: 0.010 - 3.000mV/V
S2: 0.010 - 9.999mV/V
S3: 0.10 - 30.00mV/V
Sensor sensitivity setting min. step:
S1: 0.001 mV/V
S2: 0.001 mV/V
S3: 0.01 mV/V
Default setting:
S1: 3.000 mV/V
S2: 9.999 mV/V
S3: 30.00 mV/V
Rated output from strain gauge:
S1: -30.00 – +30.00 mV, span 1.00 – 30.00 mV
S2: -99.99 – +99.99 mV, span 3.00 – 99.99 mV
S3: -300.0 – +300.0 mV, span 10.0 – 300.0 mV
Input voltage setting min. step:
S1: 0.01 mV
S2: 0.01 mV
S3: 0.1 mV
Note: Consult factory for use with a compression/tension load cells.
Excitation: 0.1 – 12.0 V adjustable (0.1 V increments)
Maximum current: 30 mA
Default setting: 1.0 V
Contact Input: TTL level (5V-CMOS level), open collector or dry contact (detecting voltage: approx. 5 V, saturation voltage: ≤ 1 V, sink current: 0.5 mA)
■ Hold Input: TTL level (5 V - CMOS level)
Commands to stop data renewal;
Choose from below:
   Hold with low or short
   Hold with high or open
(detecting voltage: approx. 5 V, saturation voltage: ≤ 1 V, sink current: 0.5 mA)

OUTPUT SPECIFICATIONS

Output Code: Code, logic and scaling are user-selectable.
  BCD with polarity (Settable range: -9999 - 9999)
  Binary with polarity (Settable range: -7FFF - 7FFF)
  Offset binary (Settable range: 0000 - FFFF)
  Two’s complement (Settable range: 8000 - 7FFF)
  Reflected binary (Settable range: 0000 - FFFF)
Output code, logic, scaling are settable.
Available number of bits
Selectable from 8, 10, 12, 14, 16 bits
Output Level
Open Collector
Max. collector-emitter voltage
: 30 V DC
Max. collector current: 30 mA
Saturation voltage: ≤1.1 V
Common: Negative
CMOS Level
H output
: ≥ 4.5 V DC
L output: ≤ 0.5 V DC
Common: Negative
POL output (Polarity): Same logic and level as for the output code; logic user-selectable
OVF output (Overflow): Same logic and level as for the output code; logic user-selectable
DAV output (Data available): Same level as for the output code; logic user-selectable

INSTALLATION

Power consumption
AC: Approx. 10 VA
DC: Approx. 7 W (300 mA at 24 V)
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 450 g (0.99 lb)

PERFORMANCE in percentage of span

Accuracy: ±0.1 %
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) of max. span
Resolution: 16 bits
Response time: ≤ 1.5 sec. (0 – 90 %)
(Update period is less than or equal to 0.3 seconds. The update pauses by auto compensation for approx. 0.8 seconds at every 5 or 6 seconds. Response time should include that time.)
Excitation: Set value ±150 mV
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute
(input to output to power)
2000 V AC @ 1 minute
(input or output or power to ground)

STANDARDS & APPROVALS

EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
Low Voltage Directive 
  EN 61010-1
  Installation Category II
  Pollution Degree 2
  Input to output to power: Basic insulation (300 V)
RoHS Directive

EXTERNAL VIEW

PARAMETER LIST

It is available to configure or confirm settings shown below by using front key pad.

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

Connection Examples

OUTPUT CONNECTOR (26-pin)

TIMING CHART

INPUT-OUTPUT RELATION EXAMPLES

• FS
-FS stands for 0 % of the input range configured by ITEM 06. +FS stands for +100 % of the input range, configured by ITEM 07.

• OVF
When one of the following conditions is true, the digital output overflows (OVF).
 1) When the input signal is out of the range between -FS and +FS.
 2) When the display value (= output signal) exceeds the display range.
 The display range differs according to output code. For example, in case of BCD with polarity, it is -9999 to 9999. Please refer to the instruction manual for detail.