ES-8579 Rev.3
GM30
Web Data Logger GM30
GRAPHICAL MAILING UNIT
Functions and Features
• Makes trend graph and status graph from the input data
• Monitors the input data and e-mail trend graph and status graph to the mobile phone and the PC
• Compatibles to Modbus/TCP client and SLMP client
• Monitors the input value and change the settings by web browser
MODEL: GM30–N-R[1]
ORDERING INFORMATION
• Code number: GM30-N-R[1]
Specify a code from below for [1].
(e.g. GM30-N-R/Q)
• Specify the specification for option code /Q
(e.g. /C01)
MODULE TYPE
N
: Standard
POWER INPUT
DC power
R
: 24 V DC
(Operational voltage range: ±10 %; ripple 10 %p-p max.)
[1] OPTIONS
blank
: none
/Q
: Options other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to our web site.)
/C01
: Silicone coating
/C02
: Polyurethane coating
FUNCTIONS & FEATURES
Acquiring and recording the input data and mailing
Connects to the remote I/O using Modbus/TCP via Ethernet, acquire and record input data from remote I/O, and send the e-mail with the images of the trend graph and the status graph.
Connects with Mitsubishi programmable controller MELSEC using SLMP to access to the data in the PLC CPU.
Sends email in accordance with the preset alarm level.
Ethernet connection settings
Various settings and maintenance can be performed using a web browser.
RELATED PRODUCTS
• PC Configurator cable
USB 2.0 compatible cable
(GM30 connector: mini-B type, 5.0m max.)
• PC configurator software (model: GM30GCFG)
Software downloadable at our web site.
GENERAL SPECIFICATIONS
Connection
RUN contact output and power
: M3 separable screw terminal (torque 0.5 N·m)
Ethernet
: RJ-45 modular jack
Solderless terminal
: Refer to the drawing at the end of the section.
Recommended manufacturer
: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,Ltd
Applicable wire size
: 0.25 to 0.75 mm
2
Screw terminal
: Nickel-plated steel
Housing material
: Flame-resistant resin (gray)
Isolation: Ethernet to RUN contact output to power to FE
Calendar clock:
Year (4 digits), month, date, day, hour, minute, second
Status Indicator LEDs
: PWR, RUN, POWER, GM30 RUN, DHCP, COM, ERROR
(Refer to Operating Manual for details)
■
RUN CONTACT OUTPUT
・RUN contact turns ON in normal conditions, and turns OFF when the power is not supplied or when an error occurs.
Rated load
: 250 V AC @ 0.5 A (cos ø = 1)
30 V DC @ 0.5 A (resistive load)
(Less than 50 V AC to conform with EU Directive)
Maximum switching voltage:
250 V AC or 30 V DC
Maximum switching power:
250 VA (AC) or 150 W (DC)
Minimum load:
5 V DC @ 10 mA
Mechanical life:
2 × 10
7
cycles (rate: 300 cycles/min.)
When driving an inductive load, external contact protection and noise quenching recommended.
■Recommended solderless terminal size - M3 (unit: mm)
ETHERNET COMMUNICATION
Communication Standard
: IEEE 802.3u
Transmission
: 10BASE-T, 100BASE-TX
Baud rate
: 10/100 Mbps (Auto Negotiation function)
Protocol
: TCP/IP, Modbus/TCP, SLMP, HTTP, SNTP
Transmission media
: 10BASE-T (STP, Category 5),
100BASE-TX (STP, Category 5e)
Max. segment length:
100 meters
Status Indicator LEDs
: DPX, LNK
IP address
: 192.168.0.10 (factory default)
INSTALLATION
Power consumption
•
DC
: Approx. 5 W 24 V DC
Operating temperature
: 0 to 50°C (32 to 122°F)
Storage temperature
: -10 to +60°C (14 to 140°F)
Operating humidity
: 10 to 90 %RH (non-condensing)
Atmosphere
: No corrosive gas or heavy dust
Mounting
: Surface or DIN rail
Weight
: 330 g (0.73 lb)
PERFORMANCE
Calendar clock
: (with battery backup)
Accuracy
: Monthly deviation 2 minutes at 25°C
Back up period
: Approx. 2 years at 25°C
Battery
: Primary lithium battery (non-removable)
(In order to prevent battery drain, battery back up is OFF at factory default. Turn it ON prior to start using.)
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 1500 V AC @ 1 minute
(Ethernet to RUN contact output to power supply to FE)
STANDARDS & APPROVALS
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EXTERNAL VIEW
TERMINAL ASSIGNMENTS
EXTERNAL DIMENSIONS unit: mm [inch]
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FE terminal to ground.
Caution: FE terminal is NOT a protective conductor terminal.
COMMUNICATION
■
IP
GM30 supports DHCP client;
Allows manual setting of IP address, subnet mask, default gateway, and DNS server.
■ MODBUS/TCP CLIENT
DL30 allows I/O expansion with remote I/Os such as R3 or R7 series;
Collectively handles data from measuring points in multiple locations.
■ CONNECTABLE DEVICES (Modbus slaves)
• DL8
• DL30
• TR30-G
• R3-NE1
• R7E series
• R9EWTU
• R6-NE1
• R6-NE2
• R5-NE1
• D3-NE1
• D3-NE2
• D5-NE1
• IB10W2
• WL40EW2
• 72EM2-M4
• GR8-EM
• IT series
■ SLMP CLIENT
GM30 allows I/O expansion by connecting with the SLMP-compatible CPU unit of Mitsubishi programmable controller MELSEC;
Collectively handles data from measuring points in multiple locations.
■ CONNECTABLE MELSEC MODEL
• MELSEC iQ-R series
• MELSEC iQ-F series
• MELSEC Q series
■ MAX. NO. OF CONNECTABLE DEVICES (No. of slaves)
• 32 (nodes) (selectable between Modbus/TCP and SLMP)
■ ETHERNET CONNECTION SETTING
Test mailing and changing settings can be performed using web browser.
Compatible Terminals & Browsers
• iOS 15.5
: Safari
• Android 11:
Chrome 103
• Windows 10
:
- Microsoft Edge 103
- Firefox 102
- Chrome 103
MAX. NO. OF CONNECTABLE DEVICES:
2
EVENT REPORTING E-MAIL
GM30 transmits an 'event reporting’ e-mail at occurrence of event, continuance of event, returning from event, or at designated time.
Encrypted communication supported. (SMTP over SSL).
• No. of e-mail recipients
: 32
• Attached file
: Trend graph and status graph
(Makes image file each time at report)
GRAPH
■TREND GRAPH
Performs sampling of trend data in 1 sec. cycle, and attach the generated image file at reporting.
· Pen
Max. 10 (Select from AI, DI and PI)
· Dot transfer
10, 15, 20, 30 sec.
1, 2, 5, 10, 15, 20, 30, 60 min.
Specify the number of times: 10 to 3600 times
· Graph
No. of data sample: Max. 1620 dots
OTHER FUNCTIONS
•Maintenance
- Various settings and operations are available from the Maintenance menu on the configurator software (model: GM30CFG).
SYSTEM CONFIGURATION EXAMPLES
Devices other than the GM30 in the configuration below shall be provided by the user.