ES-7989 Rev.8
M6SPP
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series
PULSE ISOLATOR
Functions & Features
• Maintenance-free tension clamp connection
• 5.9-mm wide ultra-slim design
• Low profile allows the M6S module mounted in a 120-mm deep panel
• Galvanically isolates pulse rate signals
• High-density mounting
• Power indicator and input monitor LED
Typical Applications
• Isolating field pulse signals in order to reduce noises
• Changing e.g. dry contact signal to e.g. 5 V signals
MODEL: M6SPP–[1][2][3]–R[4]
ORDERING INFORMATION
• Code number: M6SPP-[1][2][3]-R[4]
Specify a code from below for each of [1] through [4].
(e.g. M6SPP-CMN-R/Q)
• Specify the specification for option code /Q
(e.g. /C01)
[1] INPUT
A1
: Open collector
A2
: Mechanical contact
C
: 5 V pulse (sensitivity 2 V)
D
: 12 V/24 V pulse (sensitivity 5 V)
H
: Two-wire current pulse
[2] OUTPUT
A1
: High frequency open collector (max. 100 kHz)
A2
: Low frequency open collector (max. 30 Hz)
M
: 5 V pulse
N
: 12 V pulse
P
: 24 V pulse
[3] OUTPUT LOGIC
N
: The same as the input
R
: Inverted
POWER INPUT
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[4] OPTIONS
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to our web site.)
/C01
: Silicone coating
/C02
: Polyurethane coating
GENERAL SPECIFICATIONS
Connection
Input and output
: Tension clamp
Power input
: Via the Installation Base (model: M6SBS)
or Tension clamp
Applicable wire size
: 0.2 to 2.5 mm
2
, stripped length 8 mm
Housing material
: Flame-resistant resin (black)
Isolation
: Input to output to power
Chattering protection
: Filter provided for mechanical contact input
Power indicator LED
: Green LED turns on when the power is supplied.
Input monitor LED
Open collector, Mechanical contact
: Orange LED turns
on when the input is ON.
Voltage pulse, 2-wire current pulse
: Orange LED turns
on when the input is high.
Input pulse sensing
: DC coupled
INPUT SPECIFICATIONS
Excitation
: 12 V DC @20 mA, shortcircuit protection
■
Open Collector
Maximum frequency
: 100 kHz
Pulse width time requirement
: ≥ 5 μsec. for ON and OFF
Sensing
: Approx. 11 V DC @2.4 mA
Detecting levels
: ≤ 1.8 kΩ/3 V for ON, ≥ 4 kΩ/5 V for OFF
■
Mechanical Contact
Maximum frequency
: 30 Hz
Pulse width time requirement
: ≥ 10 msec. for ON and OFF
Sensing
: Approx. 11 V DC @2.4 mA
Detecting levels
: ≤ 1.8 kΩ/3 V for ON, ≥ 4 kΩ/5 V for OFF
■
Voltage Pulse
Maximum frequency
: 100 kHz
Pulse width time requirement
: ≥ 5 μsec. for high and low levels
Waveform
: Square or sine
Input impedance
: ≥ 10 kΩ
Max. voltage between input terminals
: 50 V
Detecting H level
5 V pulse: ≥ 3 V
12 V, 24 V pulse: ≥ 6 V
Detecting L level
5 V pulse: ≤ 1 V
12 V, 24 V pulse: ≤ 4 V
■
Two-wire Current Pulse
Max. frequency
: 100 kHz
Input resistance
: Receiving resistor 200 Ω
Input range
: 0 – 25 mA
Detecting levels
: ≤ 5 mA for Lo, ≥ 15 mA for Hi
OUTPUT SPECIFICATIONS
■
High Frequency Open Collector
:
50 V DC @100 mA (resistive load)
Maximum frequency
: 100 kHz
Saturation voltage
: 0.5 V DC
■
Low Frequency Open Collector
:
50 V DC @100 mA (resistive load)
Maximum frequency
: 30 Hz
Timer
: Limits ≥ 75 msec. within 75 ±25 msec.
ON time for output logic non-inverted
OFF time for output logic inverted
Saturation voltage
: 0.5 V DC
■
Voltage Pulse
Maximum frequency
: 100 kHz
High level
: Rating (5, 12 or 24 V) ±10 %
Low level
: ≤ 0.5 V
Load resistance
:
≥ 1.0 kΩ for 5 V
≥ 2.4 kΩ for 12 V
≥ 4.8 kΩ for 24 V
INSTALLATION
Power consumption
: Approx. 1 W
Operating temperature
: -20 to +55°C (-4 to +131°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Mounting
: Installation Base (model: M6SBS) or DIN rail
Weight
: 60 g (2.1 oz)
PERFORMANCE
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 2000 V AC @1 minute (input to output to power to ground)
STANDARDS & APPROVALS
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EXTERNAL VIEW
(With the cover open)
OUTPUT LOGIC
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM