ES-8064 Rev.7

MD7JS

Lightning Surge Protectors for
Electronics Equipment M-RESTER

LIGHTNING SURGE PROTECTOR FOR SELF-SYNCH

(ultra-slim)
Functions & Features
• High discharge current capacity 20 kA (8 / 20 μs), 1 kA (10 / 350 μs)
• Ultra-thin 7-mm-wide module can be mounted
in high density
• Excellent protection employing multi-stage SPD circuits
• DIN rail mounting and grounding
• Shield terminal provided
• Protects self-synch transmitters and converters

MODEL: MD7JS[1]

ORDERING INFORMATION

• Code number: MD7JS[1]
Specify a code from below for [1].
  (e.g. MD7JS/Q)
• Specify the specification for option code /Q
  (e.g. /C01)

[1] OPTIONS

blank: none
/Q: With options (specify the specification)

SPECIFICATIONS OF OPTION: Q

COATING (For the detail, refer to our web site.)
/C01: Silicone coating
/C02: Polyurethane coating

GENERAL SPECIFICATIONS

Construction: Slim-sized front terminal structure
Degree of protection: IP20
Connection: Euro terminal block (torque 0.3 N·m)
Applicable wire size: 0.2 – 2.5 mm2,  stripped length 8 mm
Grounding: DIN Rail
Housing material: Flame-resistant resin (black)

INSTALLATION

Operating temperature: -25 to +55°C (-13 to +131°F)
(-5 to +40°C or 23 to 104°F, 30 to 80 % RH non-condensing, for EU conformity.)
Operating humidity: 30 to 90 % RH (non-condensing)
(-5 to +40°C or 23 to 104°F, 30 to 80 % RH non-condensing, for EU conformity.)
Mounting: DIN Rail (TH35-7.5, 1-mm-thick)
Oxide film on the surface of an aluminium DIN rail may lower the electric conductivity between this module and the ground. Use a steel or copper rail.
Weight: 70 g (2.5 oz)

PERFORMANCE

Max. continuous operating voltage (Uc): 
 Line to line: ±130 V  
 Line to earth: ±160 V
Voltage protection level (Up) @ 6 kV (1.2 / 50 μs)
 Line to line: ±450 V
 Line to earth:  ±800 V
Response time:
 Line to line: ≤ 4 nsec.
 Line to earth: ≤ 20 nsec.
Leakage current @ Uc:
  Line to line: ≤ 20 μA 
  Line to earth: ≤ 5 μA
Max. discharge current (Imax): 20 kA (8 / 20 μs); 1.0 kA (10 / 350 μs)
Nominal current (IN): 500 mA
Internal series resistance: 2 Ω ±10 % per line
Surge protection: IEC 61643-21 Categories C1, C2, D1
                             EN 61643-21 Categories C1, C2, D1

STANDARDS & APPROVALS

EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
Low Voltage Directive 
  EN 61643-21
RoHS Directive

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM