ES-8202 Rev.9

MDP-TL

Lightning Surge Protectors for
Electronics Equipment M-RESTER

LIGHTNING SURGE PROTECTOR
FOR TELECOMMUNICATION LINE USE

Functions & Features
• Designed specifically to protect telecommunication equipment from lightning surges entering through telecommunication line network
• Easy connection to the protected equipment
with modular jacks
• Connection with a telephone and a modem in
parallel
• No interruption of transmission signal by unplugging the protector element

MODEL: MDP–TL[1]

ORDERING INFORMATION

• Code number: MDP-TL[1]
Specify a code from below for [1].
  (e.g. MDP-TL/A33/Q)
• Specify the specification for option code /Q
  (e.g. /C01)

[1] OPTIONS (multiple selections)

DIN Rail Mounting Adapter
blank: Without
/A33: With adapter (model A-33)
Other Options
blank: none
/Q: Option other than the above (specify the specification)

SPECIFICATIONS OF OPTION: Q

COATING (For the detail, refer to our web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating

GENERAL SPECIFICATIONS

Construction: Plug-in
Connection: Modular jack or M4 screw terminals (torque 0.8 N·m)
Modular jack cord: 6-pole, 2-core
Screw terminal: Nickel-plated steel
Housing material: Flame-resistant resin (black)

INSTALLATION

Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight:
120 g (0.26 lb), standard
145 g (0.32 lb), with DIN rail mounting adapter

PERFORMANCE

Max. continuous operating voltage (Uc): 
 Line to line: ±160 V  
 Line to earth: ±160 V
Voltage protection level (Up):
• @ 1 kV (100 A)
 Line to line: ±650 V 
 Line to earth: ±900 V
• @ 2 kV (1 kA) 
 Line to line: ±550 V
 Line to earth: ±900 V
Response time: ≤ 0.1 μsec.
Leakage current:
 Line to line: ≤ 100 μA @ ±160 V DC
 Line to earth: ≤ 100 μA @ ±160 V DC
Max. discharge current (Imax):
 Modular jack: 500 A (8 / 20 μs)
 Screw terminal: 1000 A (8 / 20 μs)
Nominal current (IN): 500 mA
Internal series resistance: ≤ 0.1 Ω (including return)
Capacitance @ 1 MHz:
 Line to line:  ≤ 1000 pF
 Line to earth: ≤ 100 pF
Surge protection: IEC 61643-21 Categories C1, C2

CONNECTION EXAMPLES

GROUNDING

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]

MOUNTING REQUIREMENTS unit: mm [inch]