ES-8465 Rev.8
R3-GD1
Remote I/O R3 Series
DeviceNet INTERFACE MODULE
(for 64-point analog signals)
Functions & Features
• Enables other protocol interface modules to communicate with DeviceNet data (gateway).
• Recognized as an analog I/O mixed module by other protocol interface modules.
• Used as DeviceNet slave device like R3-NDx.
Typical Applications
• A gateway for DeviceNet and Modbus/TCP.
MODEL: R3-GD1S[1]
ORDERING INFORMATION
• Code number: R3-GD1S[1]
Specify a code from below for [1].
(e.g. R3-GD1S/CE/Q)
• Specify the specification for option code /Q
(e.g. /C01)
COMMUNICATION MODE
S
: Single
[1] OPTIONS (multiple selections)
Standards & Approvals
blank
: Without CE
/CE
: CE marking
Other Options
blank
: none
/Q
: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to our web site.)
/C01
: Silicone coating
/C02
: Polyurethane coating
/C03
: Rubber coating
CAUTION
• When selecting network modules, note that this unit is not designed to be used with network modules of certain types or versions.
• This unit CANNOT be used with R3-NC2, R3-NEIP1, R3-NFx, and R3-NLx.
• This unit CAN be used with:
R3-NM3 and R3-NML3 of firmware version V1.00 or higher;
R3-NC1, R3-NC3, R3-NDx, R3-NE1, R3-NFL1, R3-NM1,
R3-NM4, and R3-NP1 of firmware version V2.00 or higher;
and
other models of any firmware versions.
RELATED PRODUCTS
• EDS file
(downloadable at our web site.)
GENERAL SPECIFICATIONS
Connection
Network
: Euro type connector terminal
(applicable wire size: 0.2 to 2.5 mm
2
, stripped length 7 mm)
Internal bus
: Via the Installation Base
(model: R3-BSx)
Internal
Power
: Via the Installation Base
(model: R3-BSx)
RUN contact output
: M3 separable screw terminal
(torque 0.5 N·m)
Screw terminal
: Nickel-plated steel
Isolation
: DeviceNet to internal bus or internal power to RUN contact output
Module allocation
: Set with the side DIP switch.
■
RUN CONTACT OUTPUT
RUN contact
: Turns on when both MS and NS LEDs are green (Both the DeviceNet and fieldbus on the other R3 interface module are in normal communication.)
Rated load
: 250 V AC @ 0.5 A (cos ø = 1)
30 V DC @ 0.5 A (resistive load)
(Less than 50 V AC to conform with EU Directive)
Maximum switching voltage
: 250 V AC or 30 V DC
Maximum switching power
: 250 VA or 150 W
Minimum load
: 1 V DC @ 1 mA
Mechanical life
: 2 × 10
7
cycles (300 cycles/min.)
When driving an inductive load, external contact protection and noise quenching recommended.
DeviceNet COMMUNICATION
Transmission cable
: Approved for DeviceNet
Node address setting
: DIP switch; 00 – 63
Baud rate
: 125 kbps, 250 kbps, 500 kbps DIP switch
NS (Network Status) indicator
: Bi-color (green/red) LED
indicates status of the communication link.
MS (Module Status) indicator
: Bi-color (green/red) LED
indicates device status.
Required data words
: 64 words for input data 64 words for
output data
INSTALLATION
Supply voltage to network
: 11 – 25 V DC supplied through the network terminal block
Supply current to network
: 50 mA max.
Operating temperature
: -10 to +55°C (14 to 131°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Atmosphere
: No corrosive gas or heavy dust
Mounting
: Installation Base (model: R3-BSx)
Weight
: 200 g (0.44 lb)
PERFORMANCE
Data allocation
: 16 × n (Module allocation: 1 to 4)
Current consumption
: 80 mA
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 1500 V AC @ 1 minute
(DeviceNet to internal bus or internal power to RUN contact output)
2000 V AC @ 1 minute (power input to FG; isolated on the power supply module)
STANDARDS & APPROVALS
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EXTERNAL VIEW
TRANSMISSION DATA DESCRIPTIONS
I/O DATA DESCRIPTIONS
■ ANALOG DATA
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
SYSTEM CONFIGURATION EXAMPLES
When the DeviceNet data is acquired with a PC recorder and this module as a gateway, the system configuration is as follows.