ES-8008-B Rev.1

R7I4DML3-DAC32C

Remote I/O R7I4D Series

MECHATROLINK I/O MODULE

(NPN discrete input & NPN transistor output, 16 points each, e-CON connector MECHATROLINK- III use)
Functions & Features
• 16 points NPN discrete input & 16 points NPN transistor output module for MECHATROLINK- III 

MODEL: R7I4DML3-DAC32C-B-R[1]

ORDERING INFORMATION

• Code number: R7I4DML3-DAC32C-B-R[1]
Specify a code from below for [1].
  (e.g. R7I4DML3-DAC32C-B-R/Q)
• Specify the specification for option code /Q
  (e.g. /C01/SET)

I/O TYPE

DAC32C: NPN discrete input &
  NPN transistor output, 16 points each

TERMINAL BLOCK

B: Tension clamp terminal block for power supply
    Connector for MECHATROLINK- III
    e-CON connector for I/O

POWER INPUT

DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)

[1] OPTIONS (multiple selections)

Wire Breakdown Detection
Blank: With
/D1: Without
Other Options
blank: none
/Q: With options (specify the specification)

SPECIFICATIONS OF OPTION: Q (multiple selections)

COATING (For the detail, refer to our web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
 (No. ESU-8008-DAC32C)

RELATED PRODUCTS

• PC configurator software (model: R7CFG)
Downloadable at our web site.
For connecting to PC, use commercially available Mini-B type USB cable. (provided by user)

GENERAL SPECIFICATIONS

Connection
 
MECHATROLINK-III: MECHATROLINK-III connector
  I/Oe-CON connector
  Power & Sensor excitation: Separable screwless spring terminal
Housing material: Flame-resistant resin (gray)
Isolation: Input or output or sensor excitation to MECHATROLINK or FE to power
Output at the loss of communication: Configurable via R7CFG
Status indicator LEDs: PWR, ERR, CON, LNK1, LNK2 (5 LEDs) indicate the module’s operating conditions. (Refer to the instruction manual)
Discrete I/O status indicator LED: Green LED turns on with I/O ON
Read rate: Selectable with R7CFG

MECHATROLINK-III COMMUNICATION

Baud rate: 100 Mbps
Transmission distance: 6300 m max.
Distance between stations: 100 m max.
Transmission media: MECHATROLINK cable (Model JEPMC-W6013-x-E, Yaskawa Controls Co., Ltd.)
Connector: TYCO AMP Industrial mini I/O connector
Max. number of slaves: 62
(The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit)
Transmission cycle: 125 µsec., 250 µsec., 500 µsec., 1 – 64 msec. (with 1 msec. increments)
Communication cycle: 125 µsec. through 64 msec.
Applicable profile: Standard I/O profile (cyclic communication)
 Event-driven communication acquiring ID profile (event-driven communication)
Transmission bytes: 16 bytes
Station address: 03H through EFH (set with rotary switches)
Cyclic communication: Available
Event-driven communication: Available
Slave monitoring: None

INPUT SPECIFICATIONS

Common: Positive common (NPN) per 16 points
Maximum inputs applicable at once: No limit (at 24 V DC)
Sensor excitation: 24 V DC ±10 %; ripple 5 %p-p max.,
≤ 5 A (including discrete input load charge); rated current
8 A
ON voltage / current: ≥ 15 V DC (X0 through XF to +24V) / ≥ 3.5 mA
OFF voltage / current: ≤ 5 V DC (X0 through XF to +24V) / ≤ 1.0 mA
Input current: ≤ 5.5 mA per point at 24 V DC
Input resistance: Approx. 4.4 kΩ
ON delay: ≤ 0.5 msec.
OFF delay: ≤ 0.5 msec.

OUTPUT SPECIFICATIONS

Common: Negative common (NPN) per 16 points
Maximum outputs applicable at once: No limit (at 24 V DC)
Sensor Excitation: 24 V DC ±10 %, ripple 5 %p-p max.,
≤ 5 A (including discrete output load charge); rated current
8 A
Rated output current: 0.2 A per point, 3.2 A per common
Residual voltage: ≤ 1.2 V
Leakage current:
With wire breakdown detection: ≤ 0.7 mA
Without wire breakdown detection: ≤ 0.1 mA
ON delay: ≤ 0.2 msec.
OFF delay: ≤ 0.5 msec.
Overload current protection function: Turns OFF the outputs when overcurrent is detected
Overheat protection function: Turns OFF the outputs when overheat is detected
Diagnostic function: When the overcurrent, overheat and open load (disconnection) are detected, notifies to the status bit of upper input area.  Refer to the users manual for details
Note: Status is disabled with option code: /D1 (without wire breakdown detection).
(When driving an inductive load, connect a diode in parallel with the load.)

INSTALLATION

Current consumption
DC at 24 V DC: ≤ 70 mA
Operating temperature: -10 to +55°C (14 to 131°F)
Storage temperature: -20 to +65°C (-4 to +149°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Surface or DIN rail (35 mm rail)
Weight: 170 g (0.37 lb)

PERFORMANCE

Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(input or output or sensor excitation to MECHATROLINK or FE to power)

STANDARDS & APPROVALS

EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
RoHS Directive

FUNCTIONS

WIRE BREAKDOWN DETECTION
The function to notifies to the status bit of upper input area in case of open load (disconnection) of discrete output is detected.
Connect output load under 10 kΩ.
Pull-down resister is mounted to detect disconnection so weak leakage current flows even when the output is OFF.
Status bit is disabled and pull-down resister is not mounted with option code: /D1 (withourt wire breakdown detection).

PC CONFIGURATOR

The following parameters can be set with using PC Configurator Software (model: R7CFG)
Refer to the users manual for the R7CFG for detailed operation of the software program.

EXTERNAL VIEW

TERMINAL ASSIGNMENTS

■I/O TERMINAL ASSIGNMENT

RESPONSE TIME

Response time of discrete input module is the time till when the communication ASIC of the module transmits input data from when input signal is applied to the module.
Response time of discrete output module is the time till when the module output the signal from when output data is received by the communication ASIC of the module.
TCOM: MECHATROLINK-III transmission cycle set at master
(depends on system and configuration)

TINP: Response of input module ≤ Delay of input circuit (Ta, ON delay time or OFF delay time) +  Acquire cycle (Ts) + input internal processing delay time (Tc, two transmission cycle)


TOUT: Response of output module ≤ Output internal processing delay time (Td, one minimum transmission cycle the unit can handle) + Conversion time (Te) + Delay of output circuit (Tf, ON delay time or OFF delay time)


E.g. 1: Acquire cycle: 1 msec., MECHATROLINK-III transmission cycle: 0.125 msec., discrete input ON
  Response of input module (TINP): Delay of input circuit (0.5 msec.) + Acquire cycle (1 msec.) + input internal processing delay time (0.125 msec. x 2) = 1.75 [msec.]

E.g. 2: MECHATROLINK-III transmission cycle: 0.5 msec., discrete output OFF
Response of output module (T0UT): Output internal processing delay time (0.125 msec.) + Delay of output circuit (0.5 msec.) 
= 0.625 [msec.]

I/O DATA DESCRIPTIONS

When overcurrent or overheat is detected on each channel of discrete output while the output is ON, the status bit corresponding to the output turns “1” and is latched*. Then the discrete output is also latched to OFF.
To reset the latched bit and discrete output, set this output to OFF from the host PC/PLC or turn off and on the power supply to the unit.
When disconnection (open load) is detected while output is OFF, the corresponding status bit turns “1” but is not latched.
* The status bit turns “0” if the load is opened in the state overcurrent or overheat is detected. However, the discrete output of the unit remains latched. Be sure to remove the cause of error and reset the latched output by setting the output to OFF or turning off/on the power supply

EXTERNAL DIMENSIONS unit: mm [inch]

MOUNTING REQUIREMENTS unit: mm [inch]

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

Note: In order to improve EMC performance, bond the FE terminal to ground.
Caution: FE terminal is NOT a protective conductor terminal.