ES-7776-F Rev.2
R7K4DML-B-DA32B
Remote I/O R7K4D Series
MECHATROLINK I/O MODULE
(PNP discrete input, 32 points, e-CON connector, MECHATROLINK- I/- II use)
Functions & Features
• 32 points PNP discrete input module for MECHATROLINK- I/- II
MODEL: R7K4DML-B-DA32B-R[1]
ORDERING INFORMATION
• Code number: R7K4DML-B-DA32B-R[1]
Specify a code from below for [1].
(e.g. R7K4DML-B-DA32B-R/Q)
• Specify the specification for option code /Q
(e.g. /C01)
TERMINAL BLOCK
B
: Tension clamp terminal block for power supply
Connector for MECHATROLINK- I/- II for communication
e-CON connector for I/O
I/O TYPE
DA32B:
PNP discrete input, 32 points
POWER INPUT
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[1] OPTIONS
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to our web site.)
/C01
: Silicone coating
/C02
: Polyurethane coating
/C03
: Rubber coating
GENERAL SPECIFICATIONS
Connection
MECHATROLINK
: MECHATROLINK- I/- II connector
Power & Sensor excitation
: Separable screwless spring
terminal
Input:
e-CON connector
Housing material
: Flame-resistant resin (gray)
Isolation:
Input or sensor excitation to MECHATROLINK or FE to power
Status indicator LED:
PWR, ERR, SD, RD
(Refer to the instruction manual for details)
Discrete input status indicator LED
: Green LED turns on with input ON
MECHATROLINK COMMUNICATION
MECHATROLINK m
ode
: Set with DIP switches
(MECHATROLINK-I or -II, data length; Factory setting: MECHATROLINK-II, data length 32 byte)
(Refer to the instruction manual)
Station address
: 60H - 7FH
(Function selected with Rotary SW. Factory setting: 61H). (Refer to the instruction manual)
■
MECHATROLINK-I
Baud rate
: 4 Mbps
Transmission distance
: 50 m max.
Distance between stations
: 30 cm min.
Transmission media
: MECHATROLINK cable (Model JEPMC-W6003-x-E, Yaskawa Controls Co., Ltd.)
Max. number of slaves
: 15
(The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit.)
Transmission cycle
: 2 msec. (fixed)
Data length
: 17 byte
■
MECHATROLINK-II
Baud rate
: 10 Mbps
Transmission distance
: 50 m max.
Distance between stations
: 50 cm min.
Transmission media
: MECHATROLINK cable (Model JEPMC-W6003-x-E, Yaskawa Controls Co., Ltd.)
Max. number of slaves
: 30
(The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit.)
Transmission cycle
: 0.25 msec., 0.5 msec., 1 msec., 1.5 msec., 2 msec., 2.5 msec., 3 msec., 4 msec., 8 msec.
Data length
: 17 byte / 32 byte selectable (Must choose identical data size for all stations within the network)
INPUT SPECIFICATIONS
Common
: Negative common (PNP) per 32 points
Maximum inputs applicable at once:
No limit (at 24V DC)
Sensor excitation
: 24 V DC ±10 %; ripple 5 %p-p max.,
≤ 2 A (including discrete input load charge); rated current
8 A
ON voltage / current
: ≥ 18 V DC (X0 through X1F to GND) / ≥ 2.0 mA
OFF voltage / current
: ≤ 9 V DC (X0 through X1F to GND) / ≤ 1.0 mA
Input current
: ≤ 3.0 mA per point at 24 V DC
Input resistance
: Approx. 8.6 kΩ
ON delay
: ≤ 0.5 msec.
OFF delay
: ≤ 1.0 msec.
INSTALLATION
Current consumption:
Approx. 60 mA (rated current 2 A)
Operating temperature
: 0 to 55°C (32 to 131°F)
Storage temperature
: -20 to +65°C (-4 to +149°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Atmosphere
: No corrosive gas or heavy dust
Mounting
: Surface or DIN rail (35 mm rail)
Weight
: 200 g (0.44 lb)
PERFORMANCE
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 1500 V AC @ 1 minute
(input or sensor excitaion to power)
500 V AC @ 1 minute (MECHATROLINK or FE to input or sensor excitation or power)
STANDARDS & APPROVALS
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EXTERNAL VIEW
TERMINAL ASSIGNMENTS
■ INPUT TERMINAL ASSIGNMENT
■ MECHATROLINK CONNECTION
MECHATROLINK RELATED COMMANDS
I/O DATA DESCRIPTIONS
EXTERNAL DIMENSIONS unit: mm [inch]
MOUNTING REQUIREMENTS unit: mm [inch]
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FE terminal to ground.
Caution: FE terminal is NOT a protective conductor terminal.