ES-7771-A Rev.2
R7K4FML-6-DA32
Remote I/O R7K4F Series
MECHATROLINK I/O MODULE
(NPN/PNP discrete input, 32 points, screw terminal block, MECHATROLINK- I/- II use)
Functions & Features
• 32 points NPN/PNP discrete input module for MECHATROLINK- I/- II
MODEL: R7K4FML-6-DA32-R[1]
ORDERING INFORMATION
• Code number: R7K4FML-6-DA32-R[1]
Specify a code from below for [1].
(e.g. R7K4FML-6-DA32-R/Q)
• Specify the specification for option code /Q
(e.g. /C01)
TERMINAL BLOCK
6
: Screw terminal block for power supply
Connector for MECHATROLINK-I/-II
Screw terminal block for I/O
I/O TYPE
DA32
: NPN/PNP discrete input, 32 points
POWER INPUT
DC power
R
: 24 V DC
(Operational voltage range: ±10 %; ripple 10 %p-p max.)
[1] OPTIONS
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to our web site.)
/C01
: Silicone coating
/C02
: Polyurethane coating
/C03
: Rubber coating
GENERAL SPECIFICATIONS
Connection
MECHATROLINK
: MECHATROLINK-I/-II connector
Power input, input
: M3 separable screw terminal (torque 0.5 N·m)
Solderless terminal
: Refer to the drawing at the end of the section.
Recommended manufacturer
: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,ltd
Applicable wire size
: 0.25 to 1.65 mm
2
(AWG 22 to 16)
Screw terminal
: Nickel-plated steel
Housing material
: Flame-resistant resin (gray)
Isolation
: Input to MECHATROLINK or FE to power
Status indicator LED:
PWR, ERR, SD, RD
(Refer to the instruction manual for details)
Discrete input status indicator LED
: Green LED turns on with input ON
■Recommended solderless terminal
MECHATROLINK COMMUNICATION
MECHATROLINK m
ode
: Set with DIP switches
(MECHATROLINK-I or -II, data length; Factory setting: MECHATROLINK-II; data length (32 byte)
(Refer to the instruction manual)
Station address
: 60H - 7FH
(Function selected with Rotary SW. Factory setting: 61H). (Refer to the instruction manual)
■
MECHATROLINK-I
Baud rate
: 4 Mbps
Transmission distance
: 50 m max.
Distance between stations
: 30 cm min.
Transmission media
: MECHATROLINK cable (Model JEPMC-W6003-x-E, Yaskawa Controls Co., Ltd.)
Max. number of slaves
: 15
(The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit)
Transmission cycle
: 2 msec. (fixed)
Data length
: 17 byte
■
MECHATROLINK-II
Baud rate
: 10 Mbps
Transmission distance
: 50 m max.
Distance between stations
: 50 cm min.
Transmission media
: MECHATROLINK cable (Model JEPMC-W6003-x-E, Yaskawa Controls Co., Ltd.)
Max. number of slaves
: 30
(The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit)
Transmission cycle
: 0.25 msec., 0.5 msec., 1 msec., 1.5 msec., 2 msec., 4 msec., 8 msec.
Data length
: 17 bytes / 32 bytes selectable (Must choose identical data size for all stations on one network)
INPUT SPECIFICATIONS
Common
: Positive or negative common (NPN/PNP) per 32 points
Maximum inputs applicable at once
: No limit (at 24 V DC)
Rated input voltage
: 24 V DC ±10 %; ripple 5 %p-p max.
ON voltage / current
: ≥ 15 V DC (input – COM) / ≥ 3.5 mA
OFF voltage / current
: ≤ 5 V DC (input – COM) / ≤ 1 mA
Input current
: ≤ 5.5 mA per point at 24 V DC
Input resistance
: Approx. 4.4 kΩ
ON delay
: ≤ 0.5 msec.
OFF delay
: ≤ 1.0 msec.
INSTALLATION
Current consumption
•
DC
: Approx. 55 mA
Operating temperature
: 0 to 55°C (32 to 131°F)
Storage temperature
: -20 to +65°C (-4 to +149°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Atmosphere
: No corrosive gas or heavy dust
Mounting
: Surface or DIN rail (35 mm rail)
Weight
: 330 g (0.73 lb)
PERFORMANCE
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 1500 V AC @ 1 minute (input to power)
500 V AC @ 1 minute (MECHATROLINK or FE to input or power)
STANDARDS & APPROVALS
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EXTERNAL VIEW
TERMINAL ASSIGNMENTS
■ INPUT TERMINAL ASSIGNMENT
■ MECHATROLINK CONNECTION
MECHATROLINK RELATED COMMANDS
I/O DATA DESCRIPTIONS
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
MOUNTING REQUIREMENTS unit: mm [inch]
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FE terminal to ground.
Caution: FE terminal is NOT a protective conductor terminal.