ES-8171 Rev.12
MA-100
Lightning Surge Protectors for
Electronics Equipment M-RESTER
LIGHTNING SURGE PROTECTOR FOR POWER SUPPLY
(2 A, 100 V / 110 V / 120 V AC)
Functions & Features
• Designed specifically for AC power supplies up to 2 amps
• No degradation of normal (50/60 Hz) line frequency
• Power indicator lamp provided
MODEL: MA–100[1]
ORDERING INFORMATION
• Code number: MA-100[1]
Specify a code from below for [1].
(e.g. MA-100/CE)
[1] OPTIONS
Standards & Approvals
blank
: Without CE
/CE
: CE marking
GENERAL SPECIFICATIONS
Construction
: Plug-in
Connection
: M3.5 screw terminals (torque 0.8 N·m)
Screw terminal:
Chromated steel
Housing material
: Flame-resistant resin (black)
Monitor lamp
: Green neon lamp turns on when the power is supplied.
INSTALLATION
Operating temperature
: -5 to +55°C (23 to 131°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Mounting
: Surface or DIN rail
Weight
: 330 g (0.73 lb)
PERFORMANCE
Discharge voltage (peak voltage)
Line to line: 190 V min.
Line to ground: 410 V min.
Maximum surge voltage
Line to line: 350 V max.
Line to ground: 700 V max.
(The maximum voltage that could pass through M-RESTER. Protected equipment must be able to withstand this voltage for very short time period.)
Response time
: ≤ 0.1 μsec.
Leakage current
Line to line: ≤ 1 mA at 150 V DC
Line to ground: ≤ 1 mA at 300 V DC
Max. discharge current (Imax)
: 1000 A (8/ 20 μsec.)
Max. load current
: 2 A
Voltage drop
: ≤ 2 V (50/60 Hz)
Rated line voltage
: 100 V / 110 V / 120 V AC
STANDARDS & APPROVALS
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Installation Category II
Pollution Degree 2
RoHS Directive
CONNECTION EXAMPLES
GROUNDING
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENT unit: mm [inch]
SCHEMATIC CIRCUITRY