ES-4411 Rev.3

20VS

Hybrid IC Isolation Amplifiers 20 Series

ISOLATION AMPLIFIER

(3-port isolation)
Functions & Features
• Being used for printed wiring board installation
• Isolating between input, output and power
• 24 V DC or 15 V DC power supply
Typical Applications
• Isolating the field and input or output circuit of microprocessor to reduce noise from field
• Available for manufacturers of small-lot products to omit the development of isolation circuit

VOLTAGE OUTPUT TYPE
MODEL: 20VS-4W4W-[1]

ORDERING INFORMATION

• Code number: 20VS-4W4W-[1]
Specify a code from below for [1].
  (e.g. 20VS-4W4W-R)

INPUT

Voltage
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)

OUTPUT

Voltage
4W: -10 to +10 V DC (Load resistance 3.5 kΩ min.)

[1] POWER INPUT

DC Power
R: 24 V DC
U: 15 V DC

GENERAL SPECIFICATIONS

Construction: Hybrid IC
Housing material: Flame-resistant resin (black)
Isolation: Input or preamp drive power to output to power
Zero adjustment: -0.5 to +0.5 % (bottom)
Span adjustment: 95 to 105 % (bottom)

OUTPUT SPECIFICATIONS

Preamp driver power: ±15 V, 5 mA

INSTALLATION

Power input
DC Power: Operational voltage range rated voltage ±2%
(ripple 2% p-p max.)
Approx. 20mA (load resistance 1MΩ)
30mA max. (24V DC, load resistance 3.5kΩ)
40mA max. (15V DC, load resistance 3.5kΩ)
Operating temperature: 0 to 60°C (32 to 140°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Soldering to the printed wiring board
Weight: 50 g (1.76 oz)

PERFORMANCE in percentage of span

Accuracy: ±0.1 %
Temp. coefficient:
  Offset drift 50 ppm/°C
  Span drift 100 ppm/°C
Frequency characteristics: Approx. 1 kHz, -3 dB
Response time: Approx. 0.6 msec. (0 – 90 %)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1000 V AC @1 minute
(Input or preamp drive power to output to power)

EXTERNAL DIMENSIONS unit: mm [inch]

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM