ES-3460 Rev.12
HPR
Space-saving Plug-in Signal Conditioners H-UNIT
PULSE SCALER
Functions & Features
• Converting pulse rate into convenient engineering unit for display on a totalizing counter or meter
• High-density mounting
Typical Applications
• Positive displacement flowmeters and turbine flowmeters
• Magnetic tachometers
MODEL: HPR–[1][2]–R[3]
ORDERING INFORMATION
• Code number: HPR–[1][2]–R[3]
Specify a code from below for each of [1] through [3].
(e.g. HPR-11-R/Q)
• Input frequency range (e.g. 0 – 356.7 Hz)
• Output frequency range (e.g. 0 – 1.00 Hz)
• Specify the specification for option code /Q
(e.g. /C01/S01)
[1] INPUT
1
: Dry contact (max. 100 kHz)
2
: Voltage pulse (max. 100 kHz)
[2] OUTPUT
1
: Open collector (max. frequency 20 kHz)
2
: 5 V pulse (max. frequency 20 kHz)
3
: Relay contact (max. frequency 2 Hz)
4
: 24 V pulse (max. frequency 20 Hz)
POWER INPUT
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[3] OPTIONS
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to our web site.)
/C01
: Silicone coating
/C02
: Polyurethane coating
/C03
: Rubber coating
TERMINAL SCREW MATERIAL
/S01
: Stainless steel
CAUTION
1) This unit's output waveform is not uniform due to its scaling method. The user must be aware that it may be inconvenient for certain types of application.
2) This unit is designed to accept at the maximum of 100 kHz, which may cause errors due to chattering in the input pulses.
Use input relays which do not cause chattering. Other relays could be used only with a CR filter, for 10 Hz at maximum.
3) Use the Model M2PRU instead of this unit in conjunction with the pulse output from our power transducers.
GENERAL SPECIFICATIONS
Construction
: Plug-in
Connection
: M3.5 screw terminals (torque 0.8 N·m)
Screw terminal
: Nickel-plated steel (standard) or stainless steel
Housing material
: Flame-resistant resin (black)
Isolation
: Input to output to power
Input pulse sensing:
Capacitor coupled; detecting pulse rise
Sensitivity adjustment:
Single-turn screwdriver adjustment (front); 25 mVp-p – 5 Vp-p
Scaling factor
: 0.9999 × 10
0
– 0.0001 × 10
–6
INPUT SPECIFICATIONS
■
Dry Contact
: Mechanical contact or open collector
Max. frequency
: 100 kHz
Pulse width time requirement
: 5 μsec. min. (20 msec. min. for frequencies ≤ 10 Hz)
Sensing
: Approx. 7.5 V DC @ 1 mA
ON/OFF level
: ≤ 20 kΩ for ON, ≥ 100 kΩ for OFF
■
Voltage Pulse
: Square or sine waveforms*
Max. frequency
: 100 kHz
Pulse width time requirement
: 5 μsec. min. (20 msec. min. for frequencies ≤ 10 Hz)
Input amplitude
: 25 mVp-p – 50 Vp-p
Minimum amplitude requirement
•
With duty ratio 50 ±10 %
(frequency: amplitude)
0 – 2 kHz: 25 mVp-p
0 – 20 kHz: 50 mVp-p
0 – 40 kHz: 1 Vp-p
0 – 100 kHz: 5 Vp-p
•
With duty ratio other than 50 ±10 %
(pulse width: amplitude)
5 μsec.: 5 Vp-p
10 μsec.: 3.5 Vp-p
50 μsec.: 2 Vp-p
100 μsec.: 1 Vp-p
500 μsec.: 0.5 Vp-p
Input impedance
: 100 kΩ minimum
OUTPUT SPECIFICATIONS
■
Open Collector
: 50 V DC @ 50 mA (resistive load)
Frequency range
: 0 – 20 kHz
ON pulse width
: Approx. 30 μsec.
Saturation voltage
: 0.6 V DC
■
Relay Contact
: 120 V AC @ 200 mA (cos ø = 1)
240 V AC @ 100 mA (cos ø = 1)
24 V DC @ 200 mA (resistive load)
Maximum switching voltage
: 240 V AC or 30 V DC
Maximum switching power
: 24 VA or 4.8 W
Minimum load
: 5 V DC @ 10 mA
Frequency range
: 0 – 2 Hz
ON pulse width
: Approx. 30 msec.
Relay life
: ≥ 5 × 10
7
cycles (mechanical)
≥ 10
5
cycles (electrical)
■
5 V Pulse
Frequency range
: 0 – 20 kHz
Low pulse width
: Approx. 30 μsec.
High level
: 5 V ±10 %
Low level
: ≤ 0.5 V
Load resistance
: 600 Ω minimum
■
24 V Pulse
Frequency range
: 0 – 20 Hz
High pulse width
: Approx. 30 msec.
High level
: 24 V ±10 %
Low level
: ≤ 0.5 V
Load resistance
: 800 Ω minimum
INSTALLATION
Current consumption
: Approx. 80 mA
Operating temperature
: -5 to +55°C (23 to 131°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Mounting
: Surface or DIN rail; Standard Rack Mounting Frame BX-16H available
Weight
: 200 g (0.44 lb)
PERFORMANCE
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 500 V AC @ 1 minute
(input to output to power)
1500 V AC @ 1 minute (input or output or power to ground)
EXTERNAL VIEW
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM