ES-0154 Rev.0
LCC-20-U
STRAIN GAUGE LOAD CELL
(Compression type)
Functions & Features
• Rated capacity 20 N
• Small and light
• Load measurement at locations where installation is restricted
MODEL: LCC-20-U
ORDERING INFORMATION
• Code number: LCC-20-U
GENERAL SPECIFICATIONS
Cable type:
3 dia., 4-core shielded cable,
split wire at the end
Cable length:
1 m
Body material:
stainless
Rated flexure:
0.01 mm or less
Natural frequency:
Approx. 27 kHz
INPUT SPECIFICATIONS
Rated capacity (R.C.):
20 N (2.04 kgf)
Safe
overload:
150 % R.C.
Recommended excitation voltage:
2.5 V
Maximum
excitation voltage:
5 V
Input terminal resistance:
350 Ω ±10 Ω
OUTPUT SPECIFICATIONS
Rated output (R.O.):
1 mV/V ±30 %
Output terminal resistance:
350 Ω ±10 Ω
INSTALLATION
Compensated temperature range:
0 to 50 ℃ (32 to 122 °F)
Safe temperature range:
-10 to +60 ℃ (14 to 140 °F)
Weight
:
3 g (0.11 oz)
PERFORMANCE in percentage of span
Rated output error:
±30 %
Zero balance:
±10 % R.O.
Non-linearity:
±1 % R.O.
Hysteresis:
±1 % R.O.
Repeatability:
±1 % R.O.
Temperature effect on zero:
±0.2 % R.O./℃
Temperature effect
on
output:
±0.1 % LOAD/℃
Insulation resistance:
1000 MΩ or more (B/E 50V DC)
EXTERNAL DIMENSIONS unit: mm [inch]