ES-0173 Rev.0
LCCT-2-1
STRAIN GAUGE LOAD CELL
(Tension and compression type)
Functions & Features
• Rated capacity 2 N
• Very small type
• Easy to install with female screws on both ends
MODEL: LCCT-2-1
ORDERING INFORMATION
• Code number: LCCT-2-1
GENERAL SPECIFICATIONS
Cable type:
1.6 dia., 4-core shielded cable,
split wire at the end
Cable length:
1 m
Body material:
beryllium copper
Rated flexure:
0.02 mm or less
Natural frequency:
Approx. 4.9 kHz
INPUT SPECIFICATIONS
Rated capacity (R.C.):
2 N (204 gf)
Safe overload:
200 % R.C.
Recommended excitation voltage:
5 V
Maximum excitation voltage:
10 V
Input terminal resistance:
Approx. 1000 Ω
OUTPUT SPECIFICATIONS
Rated output (R.O.):
0.5 to 1.5 mV/V
Output terminal resistance:
Approx. 1000 Ω
INSTALLATION
Compensated temperature range:
-10 to +50 ℃ (14 to
122 °F)
Safe
temperature range:
-10 to +60 ℃ (14 to 140 °F)
Weight
:
3 g (0.11 oz)
PERFORMANCE in percentage of span
Zero balance:
±50 % R.O.
Non-linearity:
±0.2 % R.O.
Hysteresis:
±0.2 % R.O.
Repeatability:
±0.1 % R.O.
Temperature effect on zero:
±0.1 % R.O./℃
Temperature effect on output:
±0.1 % LOAD/℃
Insulation resistance:
1000 MΩ or more (B/E 50V DC)
EXTERNAL DIMENSIONS unit: mm [inch]