ES-9321 Rev.6
48SV
Bargraph Indicators 48 Series
BARGRAPH INDICATOR
Functions & Features
• Displaying a process variable in graphic bargraph of 51 LED segments
• Small size
• High-density mounting
MODEL: 48SV–1R[1][2]-[3]
ORDERING INFORMATION
• Code number: 48SV-1R[1][2]-[3]
Specify a code from below for each of [1] through [3].
(e.g. 48SV-1RVA-T)
BARGRAPHS
1
: Single
BAR LED COLOR
R
: Red
[1] MOUNTING DIRECTION
V
: Vertical
H
: Horizontal
[2] INPUT
Current
A
: 4 – 20 mA DC (Input resistance 5.1Ω)
G
: 0 – 1 mA DC (Input resistance 100 Ω)
Voltage
3
: 0 – 1 V DC (Input resistance 200 kΩ)
5
: 0 – 5 V DC (Input resistance 160 kΩ)
6
: 1 – 5 V DC (Input resistance 160 kΩ)
[3] POWER INPUT
DC Power
T
: 5 V DC
(Operational voltage range 5 V ±10 %, ripple 10 %p-p max.)
R
: 24 V DC
(Operational voltage range 24 V ±15 %, ripple 10 %p-p max.)
GENERAL SPECIFICATIONS
Construction
: Panel flush mounting
Connection
: Connector (leadwires soldered)
Housing material
: ABS resin
Isolation
: Input to power
Scale plate
: Aluminium (white scale & characters on black base)
Indicator
: LED
No. of LED segments
: 52 including over-range indicator “1”
Scale length
: 50 mm (1.97”)
Scale
: 0 - 100 %
INSTALLATION
Power consumption
•
DC
: ≤ 1.5 W
Operating temperature
: 0 to 50°C (32 to 122°F)
Operating humidity
: 40 to 80 %RH (non-condensing)
Mounting
: Panel flush mounting
Weight
: 90 g (0.2 lb)
PERFORMANCE in percentage of span
Accuracy
: ±2 %
Response time
: 0.5 sec.
Insulation resistance
: ≥ 50 MΩ with 500 V DC
(input or power to ground)
Dielectric strength
: 2000 V AC @1 minute (input or power to ground)
500 V AC @ 1 minute (input to power)
CONNECTION DIAGRAM
EXTERNAL DIMENSIONS unit: mm [inch]
PANEL CUTOUT unit: mm [inch]
Panel thickness: 0.5 to 2 (.02″ to .08″)