ES-7061 Rev.1
VR4896E-G2
Paperless Recording System
PAPERLESS RECORDER
(color LCD display)
Functions & Features
• 48 × 96 mm square size
• IP55 front panel
• Records measurement data and operation status to SD card
• 100 msec. sampling rate
• SD card can be removed from the front
• Recorded data can be displayed and analyzed using the dedicated application
• DC voltage input, 2 points
• Discrete input 1 point, Photo MOSFET relay output 1 point
Usable to trigger input and alarm output
MODEL: VR4896E-G2-[1]-R[2]
ORDERING INFORMATION
• Code number: VR4896E-G2-[1]-R[2]
Specify a code from below for each of [1] and [2].
(e.g. VR4896E-G2-1-R/Q)
• Specify the specification for option code /Q
(e.g. /C01)
COMMUNICATION
E
: Ethernet communication
I/O TYPE
G2:
DC voltage input, 2 points (non-isolated),
Discrete input, 1 point,
Photo MOSFET relay output, 1 point
(For input range, refer to analog input specifications.)
[1] ANALOG INPUT RANGE
Select input range from the following (ch 1, ch 2).
1:
DC input, 2 points (wide span voltage input, 2 points)
4:
DC input, 2 points (middle span voltage input, 2 points)
6:
DC input, 2 points (narrow span voltage input, 2 points)
POWER INPUT
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[2] OPTIONS
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to our web site.)
/C01
: Silicone coating
/C02
: Polyurethane coating
/C03
: Rubber coating
RELATED PRODUCTS
• PC configurator software (model:
VR4896
CFG)
• Viewer software (model: TRViewer)
Software downloadable at our web site.
• SD card
An SD card is required to store data in the device.
Use an SD card of the specified model number.
Consult us for purchase.
- Hagiwara Solutions MSDB-016GS(V01SLS
GENERAL SPECIFICATIONS
Construction
: Panel flush mounting
Degree of protection
: IP55; ensured for the front panel of the device independently mounted to a panel
Connection
Ethernet
: RJ-45 connector
Power supply
: Separable tension clamp terminal
Applicable wire size
: 0.2 - 2.5 mm
2
,
stripped length 10 mm
I/O
: Separable tension clamp terminal
Applicable wire size
: 0.2 - 1.5 mm
2
, stripped length 10 mm
Housing material
: Flame-resistant resin (black)
Isolation
: Analog input to contact input to contact output to Ethernet or FE to power
Calendar clock:
Year (4 digits), month, date, day, hour, minute, second
■
Display
Display device
: 2.86-inch TFT LCD
Display colors
: 65 536
Resolution
: 320 × 125 pixels
Backlight
: LED
Backlight life
: Approx. 30 000 hours
(The backlight can be replaced in our factory.
The LCD must be replaced at the same time.)
Screen saver standby time
: 1 to 10 minutes
Display update interval
: 100 msec.
ETHERNET COMMUNICATION
Communication Standard
: IEEE 802.3u
Transmission
: 10BASE-T, 100BASE-TX
Baud rate
: 10/100 Mbps (Auto Negotiation function)
Protocol
: IP, TCP, UDP, ICMP, SNTP, HTTP, DHCP, SMTP, SMTPS, TLS, Modbus/TCP, SLMP, Modbus/TCP server, FTP server, FTP client, FTPS client
Transmission media
: 10BASE-T (STP, Category 5)
100BASE-TX (STP, Category 5e)
Max. length of fieldbus segment
: 100 meters
Ethernet indicator LED
: ACT, LNK
IP address
: 192.168.0.10 (factory setting)
ANALOG INPUT SPECIFICATIONS
Input signal: DC voltage, 2 points
■ Wide span voltage
Input resistance: ≥ 1 MΩ
± 10 V DC to ± 0.8 V DC
Maximum input range: ± 10.5 V DC
■ Middle span voltage
Input resistance: ≥ 100 kΩ
± 0.8 V DC to ± 80 mV DC
Maximum input range: ± 0.84 V DC
■ Narrow span voltage
Input resistance: ≥ 100 kΩ
± 80 mV DC to ± 10 mV DC
Maximum input range: ± 84 mV DC
CONTACT INPUT SPECIFICATIONS
Contact input:
Dry contact
Common
: Negative common
Rated detective voltage:
Approx. 5 V DC (internal supply)
ON voltage / resistance
: ≤ 0.5 V / ≤ 500 Ω
OFF voltage / resistance
: ≥ 4.0 V DC / ≥ 20 kΩ
Input current
: Approx. 3.8 mA
Input resistance
: Approx. 1 kΩ
ON delay
: ≤ 2.0 msec.
OFF delay
: ≤ 2.0 msec.
OUTPUT SPECIFICATIONS
Photo MOSFET relay output
Rated load voltage
: 48 V peak AC / DC
Rated output current
: 0.2 A per point
Output ON resistance
: ≤ 1 Ω
Leakage current at open circuit
: ≤ 0.1 mA
ON delay
: ≤ 50 msec.
OFF delay
: ≤ 1 msec.
(Recommended to protect the contact and to eliminate noise when driving an inductive load.)
INSTALLATION
Power consumption
•
DC
: ≤ 2.4 W, ≤ 100 mA (@ 24 V DC)
Operating temperature
: -10 to +55°C (14 to 131°F)
Operating humidity
: 10 to 90 %RH (non-condensing)
Atmosphere
: No corrosive gas or heavy dust
Mounting
: Panel flush mounting
Weight
: 240 g (0.53 lb)
PERFORMANCE
Conversion accuracy
: ±0.1 % (narrow span voltage input
± 20 mV DC: ± 0.2%, ± 10mV DC: ± 0.3%)
Conversion rate:
100 msec.
Temp. coefficient
: ±0.015 % /°C (±0.008 %/°F)
(±0.03 % /°C [±0.02 %/°F] with ± 10 mV DC)
Calendar clock
(with battery backup):
Accuracy
: Monthly deviation of ≤ 2 minutes at 25°C or 77 °F
Back up period
: Approx. 2 months
Battery
: Lithium secondary battery (non-removable)
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 1500 V AC @ 1 minute
(analog input to contact input to contact output to Ethernet or FE to power supply)
STANDARDS & APPROVALS
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EXTERNAL VIEW
TERMINAL ASSIGNMENTS
■ POWER SUPPLY TERMINAL ASSIGNMENT
■ ANALOG INPUT TERMINAL ASSIGNMENT
■ CONTACT INPUT/OUTPUT TERMINAL ASSIGNMENT
EXTERNAL DIMENSIONS unit: mm [inch]
MOUNTING REQUIREMENTS unit: mm
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FE terminal to ground.
Caution: FE terminal is NOT a protective conductor terminal.
INPUT/OUTPUT FUNCTION
Selectable I/O signals among built-in I/O and remote I/O.
• Analog input (AI): max. 4 points
• Discrete input (DI): max. 2 points
• Discrete output (DO): max. 2 points
• Operational input (OI): max. 4 points
SCREEN DISPLAY
■ Trend view
Direction:
Horizontal
Number of display points:
2 per view
Number of display views:
2
Maximum number of samples:
320
■ Overview
Number of display
points
:
4 per view
Displayed content:
Name (up to 10 characters), bargraph
Number of display views:
1
■ Digital view
Number of display
points
:
1 per view
Displayed content:
Name (full), value, bargraph
Number of display views:
4
■ Log view
Number of displayed events:
4 per page (display the latest 32 events)
Number of display views:
3 (event log, system log, communication log)
■ Maintenance
view
Used to perform setting and maintenance.
■ Screen saver
Back light can be turned off if there is no operation for a certain period of time.
■ Auto view switching
Views can be switched automatically if there is no operation for a certain period of time.
TREND DATA STORING
When an SD card is placed, trend data, event data and comment data are recorded in the internal memory and then transferred to the SD card at the specified time intervals.
■ Recording method
•
Normal recording:
Recording continuously until recording is manually stopped.
•
Trigger record
ing
(edge):
Recording up to 100 samples of data before and after the trigger condition is met, respectively.
• Trigger record
ing
(level):
Recording data during the trigger condition is met.
■
Sampling rate
• 100 ms
■
Storing rate
• 100 ms, 500 ms, 1 sec., 2 sec., 5 sec., 10 sec., 1 min.,
2 min., 5 min., 10 min., 30 min., 1 hour
■
Trend data
• Number of channels:
Max. 4 (select from AI, DI, DO, OI)
•
Number of events:
Max. 50000
sample × number of channels (per file)
■
Event
data
•
Event:
Zone transition for AI and OI,
change of DI status
•
Recorded content:
Time, event
•
Number of events:
3000 (per file)
■
Comment data
•
Maximum number of input characters:
32
•
Recorded content:
Time, comment
•
Number of events:
1000 (per file)
■ Data format
Dedicated format (binary, extension “TRD”) or CSV format (UTF-8/SJIS).
■ Data file name
Files are named YYYYMMDDhhmmss when saved to the SD card.
e.g.)
Dedicated format:
20240611100000000.TRD
CSV format:
20240611100000_T.CSV (trend)
20240611100000_E.CSV (event)
20240611100000_C.CSV (comment)
■ Auto deleting function
• When the function is disabled, recording is possible until the SD card's storage capacity is exhausted.
• When the function is enabled, if the SD card's storage capacity falls below 100MB, the oldest data will be deleted.
■ Viewer software
The data stored in the SD card can be displayed on dedicated Viewer Software (model: TRViewer). Also, data can be converted to CSV format file.
LOGGING
When an SD card is placed, each log file can be stored to the SD card.
■ Event log
Recording zone transitions for AI and OI, and events occurred when DI status changes.
■ System
log
Recording a history of operations of the device, such as turning the power ON, time adjustment, or updating the setting.
■ Communication
log
Recording a history of communications of the device such as SMTP (mail) or FTP client.
■ Storing log files
When accumulated log data exceeds 128 Kbyte, the data is finalized and stored in a file.
■ Data format
txt format (.txt)
■ Log file name
Files are named YYYYMMDDhhmmss when finalized the data.
e.g.)
20240611100000E.txt (event log)
20240611100000S.txt (system log)
20240611100000C.txt (communication log)
■ No auto deleting function
COMMUNICATION
■ IP
DHCP client function is supported. Manual setting of IP address, subnet mask, default gateway and DNS server is also available.
■ Web server
This device acts as a web server, communicates with the configurator software (model:
VR4896
CFG), and allows for setting change and maintenance.
■ Modbus/TCP client
It is possible to connect to remote I/O such as R3 or R7, etc., enabling the expansion of I/O. Moreover, it can handle data from measuring points in multiple locations.
• Connected products
R3-NE1, R3-GE1
R5-NE1
R6-NE1, R6-NE2
R7E series
R9EWTU (Exclude 32-bit access)
R30NE1
72EM2-M4
GR8-EM
DL8 series
DL30 series
TR30-G
IT series
■ SLMP client
It is possible to connect to the SLMP-compatible CPU unit of Mitsubishi programmable-controller MELSEC, enabling the expansion of I/O. Moreover, it can handle data from measuring points in multiple locations.
• Connectable model:
MELSEC iQ-R series
MELSEC iQ-F series
MELSEC Q series
■ Max. number of connectable devices (Number of servers)
2 connections (selectable from Modbus/TCP or SLMP)
Establishing connections for number of slaves connected.
Note) The number of connectable devices may depend on the specifications of each device.
■ Modbus/TCP server
2 connections
I/O data can be monitored by remote SCADA.
ALARM OUTPUT
DO designated as alarm contact output can be turned ON at event occurrence.
■ Event
• Zone output of AI, DI, OI
• Communication failure in e-mail reporting, FTP client, Modbus/TCP and SLMP
EVENT REPORTING E-MAIL
E-mail reporting function is available at event occurrence or at the specified time.
Encrypted communication is supported. (SMTP over SSL)
• Number of e-mail recipients:
8
• Number of event reporting messages:
4
• Number of regular reporting
messages
:
4
• Channel status:
AI, DI, OI, DO data status can be included in a mail.
FTP CLIENT
Files stored in the SD card can be uploaded to an FTP server.
• Supports FTPS (Explicit mode)
FTP SERVER
Reading and deleting files in the SD card by an FTP client is available.
Simultaneous connection:
1
Operation verified FTP client:
FFFTP
TIMEKEEPING
■ SNTP client
• The recorder's internal time can be adjusted automatically.
• Time adjustment is performed when the power is turned on and at the specified time.
OTHER FUNCTIONS
■ Maintenance
The dedicated configurator software (model: VR4896CFG) is used to configure the device.
■ Setting file
It is possible to save the settings of the device and network to an SD card as a configuration file (vr4896cfg.json) and a network configuration file (vr4896net.json).
It is possible to configure the device by reading the configuration file in the SD card.
SYSTEM CONFIGURATION EXAMPLES
Devices other than the VR4896E-G2 in below shall be provided by the user.