ES-7732 Rev.1
R7K4GC-DC32A
Remote I/O R7K4G Series
CC-Link I/O MODULE
(NPN transistor output, 32 points, tension clamp terminal)
Functions & Features
• Remote I/O module to input/output digital I/O signal to field bus (CC-Link)
MODEL: R7K4GC-DC32A-C-R
ORDERING INFORMATION
• Code number: R7K4GC-DC32A-C-R
I/O TYPE
DC32A
: NPN transistor output, 32 points
TERMINAL BLOCK
C
: Tension clamp terminal for power
Tension clamp terminal for communication
Tension clamp terminal for I/O
POWER INPUT
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
RELATED PRODUCTS
• CSP+ file
The CSP+ file are downloadable at our web site.
CSP+ file is also downloadable at CC-Link Partner Association's web site.
GENERAL SPECIFICATIONS
Connection
: Tension clamp terminal
Housing material
: Flame-resistant resin (gray)
Isolation
: Output or exc. supply to CC-Link to power supply to FE1
Discrete output status indicator LED
: Green LED; turns on with output ON
CC-Link COMMUNICATION
Transmission:
CC-Link Ver.1.10
Network cable
: CC-Link cable designated by Mitsubishi Electric
Station Type
: Remote I/O device
Data allocation
: 1
Station number
: 1 - 64 (rotary switch, default:00)
Baud rate setting
: 156 kbps (default), 625 kbps, 2.5 Mbps,
5 Mbps, 10 Mbps (DIP switch)
Terminating resistor
: Built-in (DIP Switch, default: disable)
Status indicator LEDs
: PWR, RUN, ERR, SD, RD
(For details, refer to the users manual.)
OUTPUT SPECIFICATIONS
Common
: Negative common (NPN) per 32 points
Number of output
: 32 points
Maximum outputs applicable at once
: No limit (at 24 V DC)
Rated load voltage
: 24 V DC ±10 %, ripple 5 %p-p max.
Rated output current
: 0.1 A per point, 3.2 A per common
Residual voltage
: ≤ 1.2 V
Leakage current
: ≤ 0.1 mA
ON delay
: ≤ 0.2 msec.
OFF delay
: ≤ 0.5 msec.
Overload current protection function:
Limits the current value when overcurrent is detected
Overheat protection function:
Turns OFF the outputs when overheat is detected
(When driving an inductive load, connect a diode in parallel with the load.)
INSTALLATION
Current consumption
•
DC
at 24 V DC
: ≤ 60 mA
Operating temperature
: -10 to +55°C (14 to 131°F)
Storage temperature
: -20 to +65°C (-4 to +149°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Atmosphere
: No corrosive gas or heavy dust
Mounting
: Surface or DIN rail (35 mm rail)
Weight
: 150 g (0.33 lb)
PERFORMANCE
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength:
1500 V AC @ 1 minute
(output or exc. supply to communication/power supply)
STANDARDS & APPROVALS
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EXTERNAL VIEW
CONNECTION DIAGRAMS
TERMINAL ASSIGNMENTS
■ POWER SUPPLY TERMINAL ASSIGNMENT
■ CC-LINK TERMINAL ASSIGNMENT
■ OUTPUT TERMINAL ASSIGNMENT
DATA ALLOCATION
I/O DATA DESCRIPTIONS
EXTERNAL DIMENSIONS unit: mm [inch]
MOUNTING REQUIREMENTS unit: mm [inch]
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FE1 terminal to ground.
Caution: FE1 terminal is NOT a protective conductor terminal.