Bargraph Indicators 49 Series
BARGRAPH INDICATING ALARM
Functions & Features
• Bargraph and digital displays
• DIN size
• Easy-to-read tri-color LED indicator
Typical Applications
• Indicator for various signals
• Available to use alarm with display
MODEL: 49AV3-[1]W1[2]-[3][4]
ORDERING INFORMATION
• Code number: 49AV3-[1]W1[2]-[3][4]
Specify a code from below for each of [1] through [4].
(e.g. 49AV3-4W1A-M2/Q)
• Specify the specification for option code /Q
(e.g. /SET)
[1] ALARM OUTPUT
0
: None
2
: 2 points
4
: 4 points
BAR LED COLOR
W
: 3 colors (red, green, amber)
DIGITAL DISPLAY
1
: With
[2] INPUT
Current
A
: 4 – 20 mA DC (Input resistance 10 Ω)
D
: 0 – 20 mA DC (Input resistance 10 Ω)
G
: 0 – 1 mA DC (Input resistance 200 Ω)
Z
: Specify current (See INPUT SPECIFICATIONS)
( 0 % input must be 0 mA.)
Voltage
3
: 0 – 1 V DC (Input resistance 1 MΩ min.)
4
: 0 – 10 V DC (Input resistance 1 MΩ min.)
5
: 0 – 5 V DC (Input resistance 1 MΩ min.)
6
: 1 – 5 V DC (Input resistance 1 MΩ min.)
0
: Specify voltage (See INPUT SPECIFICATIONS)
( 0 % input must be 0 V.)
[3] POWER INPUT
AC Power
M2
: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±15 %, ripple 10 %p-p max.)
[4] OPTIONS
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
EX-FACTORY SETTING
/SET
: Preset according to the Ordering Information Sheet
(No. ESU-9334)
GENERAL SPECIFICATIONS
Construction
: Panel flush mounting
Connection:
M3 separable screw terminal (torque 0.5 N·m)
Solderless terminal
: Refer to the drawing at the end of the section.
Recommended manufacturer
: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,ltd
Applicable wire size
: 0.25 to 1.65 mm
2
(AWG 22 to 16)
Screw terminal
: Nickel-plated steel
Housing material
: Flame-resistant resin (black)
Isolation
: Input to alarm output to power
Scale plate
: Flame resistant resin (white scale & characters on black base)
Power outage protection
: Setting value backup with non-volatile RAM
Setpoint adjustment
2 points
:
H [L setpoint ] to 100 %
L 0 % to [H setpoint]
or No alarm trip
P contact is on when all conditions of the alarm output are
not met.
4 points
:
HH [H setpoint] to 100 %
H [L setpoint] to [HH setpoint]
L [LL setpoint] to [H setpoint]
LL 0 % to [L setpoint]
or No alarm trip
P contact is on when all conditions of the alarm output are
not met.
Setting
: (Front button)
• Zero and span adjustments
• Alarm setpoint
• Others
(Refer to the instruction manual for details)
Read rate
: 20/sec.
Moving average sample number
: Off (factory setting; field selectable among off, 2, 4, 8 or 16)
■
BARGRAPH
LED:
51-segment LED, 89 mm (3.50”), 120°
Display range
: 0 to 100 (scaling function not available)
(0 % or 100 % position bar blinks when the range is exceeded.)
■
DIGITAL DISPLAYS
LED
: 7-segment red LED, character 10 mm (.39”) high
Number of digits
: 4
Scaled range
: -1999 to 9999
(Min. 3 significant digits)
Display range
: -15 to +115 % of input span
(within the range of -1999 to 9999)
Decimal point position
: 10
–1
, 10
–2
, 10
–3
or none
Default setting
: 0.0 to 100.0
Zero indication
: Higher-digit zeros are suppressed
Engineering unit indication
: Sticker label attached
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,
cm, mm, m, m/sec, mm/min, cm/min, m/min,
m/h, m/s
2
, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m
3
, m
3
/sec,
m
3
/min, m
3
/h, Nm
3
/h, N·m, N/m
2
, g, kg, kg/h,
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,
kJ, MJ, rpm, sec, min, min
-1
, pH, %, ppm, etc.
■
LEDS
HH, H: Red
L, LL: Green
S, P, Z: Amber
■Recommended solderless terminal
INPUT SPECIFICATIONS
■
DC Current
: 0 – 50 mA DC; input resistor incorporated
Minimum span
: 1 mA
When specifying a resistance value, choose from below.
5.1 Ω, 10 Ω, 12 Ω, 20 Ω, 39 Ω, 200 Ω
(0.125 W ≥ [Input current]
2
× R)
■
DC Voltage:
0 – 10 V DC
Minimum span:
0.1 V
Input resistance:
≥ 1 MΩ
OUTPUT SPECIFICATIONS
■
Alarm Output
Rated load
: 250 V AC @ 1 A (cos ø = 1)
30 V DC @ 3 A (resistive load)
Maximum switching voltage
: 250 V AC, 30 V DC
Maximum switching power
: 380 VA (AC), 90 W (DC) (resistive load)
Minimum load
: 5 V DC @ 100 mA
Mechanical life
: ≥ 5 × 10
6
cycles (rate 180 cycles/min.)
INSTALLATION
Power consumption
•
AC
:
Approx. 5 VA at 100 V
Approx. 6.5 VA at 200 V
Approx. 7.5 VA at 264 V
•
DC
: Approx. 3 W
Operating temperature
: -5 to +55°C (23 to 131°F)
Operating humidity
: 10 to 90 %RH (non-condensing)
Mounting
: Panel flush mounting
Weight
: 500 g (1.1 lb)
PERFORMANCE in percentage of span
Accuracy
Bargraph
: ±2 % ±1 digit
Digital indicator
: ±0.5 % ±1 digit
(When the zero position of bargraph is changed, input below 0% is out of conformance range.)
Temp. coefficient
: ±0.015 % of FS/°C (±0.008 % of FS/°F)
Response time
: ≤ 0.5 sec.
(when moving average sample number is set to off)
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 2000 V AC @ 1 minute (input to power)
1500 V AC @ 1 minute (input or power to alarm output)
2000 V AC @ 1 minute (input or alarm output or power to ground)
EXTERNAL VIEW
CONNECTION DIAGRAM
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
PANEL CUTOUT unit: mm [inch]