ES-5542 Rev.0

W2YPD

Space-saving Dual Output Signal Conditioners
Mini-MW Series

RS-422 PULSE ISOLATOR

Functions & Features
• Converts RS-422 line driver pulse to open collector pulse
• High-density mounting
 

MODEL: W2YPD–J[1][2][3][4]-[5][6]

ORDERING INFORMATION

• Code number: W2YPD-J[1][2][3][4]-[5][6]
Specify a code from below for each of [1] through [6].
  (e.g. W2YPD-J26RN-M2/CE/Q)
• Specify the specification for option code /Q
  (e.g. /C01/S01)

INPUT

J: RS-422 line driver pulse

[1] OUTPUT 1

1: Open collector (max. frequency 100 kHz)
2: 3.3 V pulse (max. frequency 200 kHz)
3: 5 V pulse (max. frequency 200 kHz)
4: 10 V pulse (max. frequency 200 kHz)
5: 12 V pulse (max. frequency 200 kHz)

[2] OUTPUT 2

Y: None
1: Open collector (max. frequency 100 kHz)
2: 3.3 V pulse (max. frequency 200 kHz)
3: 5 V pulse (max. frequency 200 kHz)
4: 10 V pulse (max. frequency 200 kHz)
5: 12 V pulse (max. frequency 200 kHz)
6: RS-422 line driver pulse (max. frequency 200 kHz)

[3] OUTPUT 1 LOGIC

N: The same as the input
R: Inverted

[4] OUTPUT 2 LOGIC

N: The same as the input
R: Inverted
Y: None

[5] POWER INPUT

AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
 47 – 66 Hz)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)

[6] OPTIONS (multiple selections)

Standards & Approvals (must be specified)
/CE: CE marking
Other Options
blank: none
/Q: Option other than the above (specify the specification)

SPECIFICATIONS OF OPTION: Q (multiple selections)

COATING (For the detail, refer to our web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
TERMINAL SCREW MATERIAL
/S01: Stainless steel

GENERAL SPECIFICATIONS

Construction: Plug-in
Connection: M3 screw terminals (torque 0.8 N·m)
Screw terminal: Chromated steel (standard) or stainless steel
Housing material: Flame-resistant resin (black)
Isolation: Input to output 1 to output 2 to power
Frequency range: Input and output are the same.

INPUT SPECIFICATIONS

RS-422 Line Driver Pulse
Maximum frequency: 200 kHz
Receiver: Conforms to RS-422
(No receiving resistor incorporated)

OUTPUT SPECIFICATIONS

Open collector
Max. frequency: 100 kHz
Rating: 40 V DC @ 100 mA
Saturation voltage: 0.5 V DC
Voltage Pulse
Maximum frequency: 200 kHz
High level: Rating (3.3, 5, 10 or 12 V) ±20 %
Low level: ≤ 0.5V
Load resistance:
≥ 660 Ω for 3.3 V
≥ 1 kΩ for 5 V
≥ 2.0 kΩ for 10 V
≥ 2.4 kΩ for 12 V
RS-422 Line Driver Pulse: Conforms to RS-422
Max. frequency: 200 kHz
Output current: ±20 mA

INSTALLATION

Power Consumption
AC:
 ≤ 5 VA at 100 V
 ≤ 6 VA at 200 V
 ≤ 7 VA at 264 V
DC: ≤ 3 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 200 g (0.44 lb)

PERFORMANCE

Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute (input to output
1 to output 2 to power to ground)

STANDARDS & APPROVALS

EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
Low Voltage Directive 
  EN 61010-1
  Measurement Category II (output)
  Installation Category II (power)
  Pollution Degree 2
  Input or output 1 or output 2 to power input:
  Reinforced insulation (300 V)
  Input to output 1 to output 2: Basic insulation (300 V)
RoHS Directive

OUTPUT LOGIC

Applicable for both Output 1 and 2.

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM