ES-7801-C Rev.0
R7C-RS4
Remote I/O R7 Series
CC-Link I/O MODULE
(CC-Link V.1.10; RTD input, 4 points, isolated)
Functions & Features
• 4 points RTD input module for CC-Link
• Extension module can be connected
• Input sensor type can be selected with the front DIP switches for all channels.
• Individual channels, zero adjustment, span adjustment, scaling, and temperature unit can be set with the configurator software (model: R7CON)
MODEL:R7C–RS4-R[1]
ORDERING INFORMATION
• Code number: R7C-RS4-R[1]
Specify a code from below for [1].
(e.g. R7C-RS4-R/Q)
• Specify the specification for option code /Q
(e.g. /C01)
If you need factory setting, use Ordering Information Sheet (No. ESU-7801-C).
I/O TYPE
RS4
: RTD input, 4 points
POWER INPUT
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[1] OPTIONS
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to our web site.)
/C01
: Silicone coating
/C02
: Polyurethane coating
/C03
: Rubber coating
RELATED PRODUCTS
• PC Configurator cable (model: MCN-CON or COP-US)
• PC configurator software (model: R7CON)
• CSP+ file
The configurator software and CSP+ file are downloadable at our web site.
CSP+ file is also downloadable at CC-Link Partner Association's web site.
• Discrete input extension module (model: R7C-EAx)
• Discrete output extension module (model: R7C-ECx)
PACKAGE INCLUDES...
• Terminating resistor (110 Ω, 0.5 W)
GENERAL SPECIFICATIONS
Connection:
M3 separable screw terminal (torque 0.5 N·m)
Solderless terminal
: Refer to the drawing at the end of the section.
Recommended manufacturer
: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,ltd
Applicable wire size
: 0.25 to 1.65 mm
2
(AWG 22 to 16)
Screw terminal
: Nickel-plated steel
Housing material
: Flame-resistant resin (gray)
Isolation
: Input 0 to input 1 to input 2 to input 3 to power to CC-Link or FG
Zero adjustments
: Configurable via R7CON
Span adjustments
: Configurable via R7CON
Extension:
No extension (*), Discrete input 8 or 16 points, Discrete output 8 or 16 points
Selectable with the front DIP SW
(*) Factory default setting
Conversion rate
: Selectable with the front DIP SW
Burnout setting
: Selectable between upscale (*) and downscale with the front DIP switch
(*) Factory default setting
Linearization
: Standard
RTD Setting
: Configurable via the front DIP switch or R7CON
Status indicator LED
: PWR
Configurator connection
: 2.5 dia. miniature jack
■Recommended solderless terminal
CC-Link COMMUNICATION
CC-Link:
Ver.1.10
Connector
: M3 screw terminal
Network cable
: CC-Link cable designated by Mitsubishi Electric
Station number
: 1 - 64 (rotary switch, default:00)
Station Type
: Remote device
Data allocation
: 1
Baud rate setting
: 156 kbps (default), 625 kbps, 2.5 Mbps,
5 Mbps, 10 Mbps (rotary switch)
Status indicator LEDs
: RUN, ERR, SD, RD
INPUT SPECIFICATIONS
Input resistance
: ≥ 1 MΩ
Maximum leadwire resistance
: 100 Ω per wire
Sensing current
: ≤ 1 mA
INSTALLATION
Current consumption
•
DC
: Approx. 90 mA
Operating temperature
: -10 to +55°C (14 to 131°F)
Storage temperature
: -20 to +65°C (-4 to +149°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Atmosphere
: No corrosive gas or heavy dust
Mounting
: DIN rail (35 mm rail)
Weight
: 200 g (0.44 lb)
PERFORMANCE
Conversion accuracy
: ±1°C (±1.8°F)
(±3°C [±5.4°F] for Cu 10 @ 25°C)
Conversion rate
: 250 msec. (*) or 500 msec. selectable
(*) Factory default setting
Converted data range
:
• Engineering unit value (°C, K) × 10 (integer)
• Engineering unit value (°F)
Temperature coefficient
: ±0.015 %/°C (±0.008 %/°F) of max. span except ±0.150 %/°C (±0.08 %/°F) for Cu 10 @ 25°C
Response time
: Conversion rate × 2 + 50 msec. (0 – 90 %)
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 1500 V AC @ 1 minute (input 0 to input 1 to input 2 to input 3 to power to CC-Link or FG)
STANDARDS & APPROVALS
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EXTERNAL VIEW
COMMUNICATION CABLE CONNECTIONS
TERMINAL ASSIGNMENTS
■ INPUT TERMINAL ASSIGNMENT
INDICATOR LED
DATA CONVERSION
DATA ALLOCATION
I/O DATA DESCRIPTIONS
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FG terminal to ground.
Caution: FG terminal is NOT a protective conductor terminal.