ES-7805-A Rev.0
R7ML-SV4
Remote I/O R7 Series
MECHATROLINK I/O MODULE
(DC voltage/current input, 4 points, isolated, MECHATROLINK-I / -II use)
Functions & Features
• 4 points DC voltage/current input module for MECHATROLINK -I/ -II
• Extension module can be connected
• Input range can be selected with the front DIP switches for all channels
• Individual channels, zero adjustment, span adjustment, and scaling can be set with the configurator software (model: R7CON)
MODEL:R7ML–SV4-R[1]
ORDERING INFORMATION
• Code number: R7ML-SV4-R[1]
Specify a code from below for [1].
(e.g. R7ML-SV4-R/Q)
• Specify the specification for option code /Q
(e.g. /C01)
I/O TYPE
SV4
: DC voltage/current input (10 V/20 mA), 4 points
POWER INPUT
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[1] OPTIONS
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to our web site.)
/C01
: Silicone coating
/C02
: Polyurethane coating
/C03
: Rubber coating
RELATED PRODUCTS
• PC Configurator cable (model: MCN-CON or COP-US)
• PC configurator software (model: R7CON)
Downloadable at our web site.
• Discrete input extension module (model: R7ML-EAx)
• Discrete output extension module (model: R7ML-ECx)
GENERAL SPECIFICATIONS
Connection
MECHATROLINK
: MECHATROLINK-I/-II connector
Power input, input
: M3 separable screw terminal (torque 0.5 N·m)
Solderless terminal
: Refer to the drawing at the end of the section.
Recommended manufacturer
: Japan Solderless Terminal MFG. Co., Ltd., Nichifu Co., Ltd.
Applicable wire size
: 0.25 to 1.65 mm
2
(AWG 22 to 16)
Screw terminal
: Nickel-plated steel
Housing material
: Flame-resistant resin (gray)
Isolation
: Input 0 to input 1 to input 2 to input 3 to MECHATROLINK or FG to power
Zero adjustments
: Configurable via R7CON
Span adjustments
: Configurable via R7CON
Input range
: Selectable with the DIP SW on the front of the unit or configurable via R7CON
Extension:
No extension (*), Discrete input 8 or 16 points, Discrete output 8 or 16 points
Selectable with the front DIP SW
(*) Factory default setting
Conversion rate
: Selectable with the front DIP SW
Status indicator LEDs
: PWR, RUN, ERR, SD, RD
(Refer to the instruction manual)
Configurator connection
: 2.5 dia. miniature jack
■Recommended solderless terminal
MECHATROLINK COMMUNICATION
MECHATROLINK m
ode
: Set with DIP switches
(MECHATROLINK-I or -II, data length; Factory default setting: MECHATROLINK-II; data length (17 bytes)
(Refer to the instruction manual)
Station address
: 60H - 7FH
(Function selected with Rotary SW. Factory default setting: 60H) (Refer to the instruction manual)
■
MECHATROLINK-I
Baud rate
: 4 Mbps
Transmission distance
: 50 m max.
Distance between stations
: 30 cm min.
Transmission media
: MECHATROLINK cable (Model JEPMC-W6003-x-E, Yaskawa Controls Co., Ltd.)
Max. number of Subordinate Devices
: 15
(The maximum number of Subordinate Devices might change depending on the Main Device unit. Refer to the manual of the Main Device unit)
Transmission cycle
: 2 msec. (fixed)
Data length
: 17 bytes
■
MECHATROLINK-II
Baud rate
: 10 Mbps
Transmission distance
: 50 m max.
Distance between stations
: 50 cm min.
Transmission media
: MECHATROLINK cable (Model JEPMC-W6003-x-E, Yaskawa Controls Co., Ltd.)
Max. number of Subordinate Devices
: 30
(The maximum number of Subordinate Devices might change depending on the Main Device unit. Refer to the manual of the Main Device unit)
Transmission cycle
: 0.5 msec., 1 msec., 1.5 msec., 2 msec., 4 msec., 8 msec.
Data length
: 17 bytes / 32 bytes selectable (Must choose identical data size for all stations on one network)
INPUT SPECIFICATIONS
■
DC Current
Input resistor
: 70 Ω
Input range
: -20 to +20 mA DC, 0 to 20 mA DC,
4 to 20 mA DC
■
Narrow span voltage
Input resistance
: ≥ 100 kΩ
Input range
: :-1 to +1 V DC, 0 to 1 V DC, -0.5 to +0.5 V DC
■
Wide span voltage
Input resistance
: ≥ 1 MΩ
Input range
: :-10 to +10 V DC (*), -5 to +5 V DC,
0 to 10 V DC, 0 to 5 V DC, 1 to 5 V DC
(*) Factory default setting
INSTALLATION
Current consumption
•
DC
: Approx. 70 mA
Operating temperature
: 0 to 55°C (32 to 131°F)
Storage temperature
: -20 to +65°C (-4 to +149°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Atmosphere
: No corrosive gas or heavy dust
Mounting
: DIN rail (35 mm rail)
Weight
: 220 g (0.49 lb)
PERFORMANCE
Conversion rate / conversion accuracy
:
10 msec./±0.8 %, 20 msec./±0.4 %, 40 msec./±0.2 %, 80 msec./±0.1 % (*)
(*) Factory setting
Data range
: 0 – 10000 of the input range
(Scaling of converted data is configurable with the configurator software (model: R7CON))
Temp. coefficient
: ±0.015 %/°C (±0.008 %/°F)
Response time
: Conversion rate × 2 + 50 msec. (0 – 90 %)
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength:
1500 V AC @ 1 minute
(input 0 to input 1 to input 2 to input 3 to power)
500 V AC @ 1 minute (MECHATROLINK or FG to input or power)
STANDARDS & APPROVALS
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EXTERNAL VIEW
COMMUNICATION CABLE CONNECTIONS
TERMINAL ASSIGNMENTS
■ INPUT TERMINAL ASSIGNMENT
MECHATROLINK RELATED COMMANDS
DATA CONVERSION
I/O DATA DESCRIPTIONS
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FG terminal to ground.
Caution: FG terminal is NOT a protective conductor terminal.