ES-7803-BB Rev.0
R7M-DC4G
Remote I/O R7 Series
MODBUS I/O MODULE
(relay c contact output, 4 points, 115.2 kbps)
Functions & Features
• 4 points relay c contact output module for Modbus
MODEL:R7M–DC4G-R[1]
ORDERING INFORMATION
• Code number: R7M-DC4G-R[1]
Specify a code from below for [1].
(e.g. R7M-DC4G-R/Q)
• Specify the specification for option code /Q
(e.g. /C01/SET)
I/O TYPE
DC4G
: Relay c contact output, 4 points
POWER INPUT
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[1] OPTIONS
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to our web site.)
/C01
: Silicone coating
/C02
: Polyurethane coating
/C03
: Rubber coating
EX-FACTORY SETTING
/SET
: Preset according to the Ordering Information Sheet
(No. ESU-7803-BB)
CAUTION
• Extension modules cannot be connected.
RELATED PRODUCTS
• PC Configurator cable (model: MCN-CON or COP-US)
• PC configurator software (model: R7CON)
Downloadable at our web site.
GENERAL SPECIFICATIONS
Connection:
M3 separable screw terminal (torque 0.5 N·m)
Solderless terminal
: Refer to the drawing at the end of the section.
Recommended manufacturer
: Japan Solderless Terminal MFG. Co., Ltd., Nichifu Co., Ltd.
Applicable wire size
: 0.25 to 1.65 mm
2
(AWG 22 to 16)
Screw terminal
: Nickel-plated steel
Housing material
: Flame-resistant resin (gray)
Isolation
: Output to Modbus or FG to power
Output at the loss of communication
:
Hold the output (*), B contact output
Selectable with the front DIP SW
(*) factory default setting
Status indicator LEDs
: PWR, RUN, ERR, SD, RD
(Refer to the instruction manual)
Discrete
output
status indicator LED
: LED turns on with output ON
Configurator connection
: 2.5 dia. miniature jack
■Recommended solderless terminal
MODBUS COMMUNICATION
Standard
: Conforms to TIA/EIA-485-A
Transmission distance
: 500 meters max.
Transmission media
: Shielded twisted-pair cable
(CPEV-S 0.9 dia.)
Communication parameter:
With Configurator Software (model: R7CON)
• Data Mode
: RTU (default) or ASCII
• Parity:
NONE (default), ODD or EVEN
• Data bit:
8: RTU (default), 7: ASCII
•
Stop bit:
1 or 2 (default)
Baud rate setting
: With rotary switch
115.2 kbps, 57.6 kbps, 38.4 kbps (default), 28.8 kbps,
19.2 kbps, 14.4 kbps, 9600 bps, 4800 bps, 2400 bps,
1200 bps
Node address setting
: 1 - 99 (with rotary switch) (factory default setting: 00)
Terminating resistor
: Built-in (Selected with the DIP SW; factory setting: disabled)
OUTPUT SPECIFICATIONS
Common
: 1 common per 1 point
Maximum load current
: 2.0 A per point
Maximum outputs applicable at once
: No limit (at 24 V DC)
Output supply voltage/current
: 24 V DC ±10 %/ approx. 70 mA
Rated load
: 250 V AC
*1
@ 2 A (cos ø = 1),
30 V DC @ 2 A (resistive load)
*1. > 50 V AC when it is used as a product relevant to EU directive.
Maximum switching voltage
: 250 V AC, 30 V DC
Maximum switching power
: 500 VA (AC), 60 W (DC)
Minimum applicable load
: 5 V DC @ 10 mA
Mechanical life:
10
7
cycles (300 cycles per min.)
When driving an inductive load, external contact protection and noise quenching recommended.
ON delay time
: ≤ 10 msec.
OFF delay time
: ≤ 10 msec.
INSTALLATION
Current consumption
•
DC
: Approx. 35 mA
•
Relay driving current
: Approx. 70 mA
Operating temperature
: -10 to +55°C (14 to 131°F)
Storage temperature
: -20 to +65°C (-4 to +149°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Atmosphere
: No corrosive gas or heavy dust
Mounting
: DIN rail (35 mm rail)
Weight
: 200 g (0.44 lb)
PERFORMANCE
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 1500 V AC @ 1 minute (output to Modbus or FG to power)
STANDARDS & APPROVALS
Refer to the manuals to comply with the standards.
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EXTERNAL VIEW
COMMUNICATION CABLE CONNECTIONS
TERMINAL ASSIGNMENTS
■ OUTPUT TERMINAL ASSIGNMENT
MODBUS FUNCTION CODES & SUPPORTED CODES
MODBUS I/O ASSIGNMENT
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FG terminal to ground.
Caution: FG terminal is NOT a protective conductor terminal.